Security requirements – RADWAG PUE C indicator User Manual

Page 6

Advertising
background image

EXI-01-04-06-14-GB

- 6 -

2.

SECURITY REQUIREMENTS


Please read this manual carefully prior the first usage. Following the
instruction, use the device as intended;

PUE C/31H/EX indicator, and scales with design based on the indicator,
can be used in explosive zone 1 and 2 where there is a mixtures of gases,
vapours and mists of II (second) explosion group and T1, T2, T3 or T4
temperature class.
WPT………/EX and WTC………/EX scales, because of the construction of
non-electric part of the platform and used materials, can be operated in 1
and 2 zone where there are mixtures of gases, vapours and mists of IIA,
IIB, or IIC group – according to „Technical Documentation” of the scale.

Anti-explosive safety of the PUE C/31H/EX indicator, and of scales
with design based on the indicator is assured by:

• Power supplied from the ZRi02 power supplier

II (2) G [Ex

ib] IIC KDB 06ATEX251 manufactured by RADWAG, placed
behind the hazardous area or from another adapter with
appropriate parameters of intrinsically safe electrical circuit.

• Intrinsically safe design of PUE C/31H/EX indicator complying

with:
EN 60079-0 and EN 60079-11 standards, confirmed by
KDB 06ATEX250 certificate

• Using load cells certified for conformity with ATEX directive (on

anti-explosion safety)

• Making non-electric parts pf the scale in compliance with EN

13463-1 standard

Observing recommendations in this manual by users

- marking of paragraphs crucial for anti-explosion safety