2.1. ATEX marking – symbols meaning





























Electrical equipment -
compatible with one or
few kinds of anti-
explosion designs

Explosive atmosphere:
G – caused by gas,

vapor and mist.

D – caused by dust.

Symbol of the
used anti-explosion
design type

:

o – oil protection
p – gas protection with an

excess pressure

q – sand protection
d – flame-proof protection
e – strengthened design
ia -

intrinsically safe design

for operation in zone
0,1,2,

ib -

intrinsically safe design

for operation in zone 1,2,

Gas explosiveness group -
examples:
-IIA: propane (T1)

benzene (T3)
butane (T2)
ethanol (T2)

-IIB: ethylene (T2)
-IIC: acetylene (T2)

hydrogen (T1)

Temperature class –
surface max temperature
of the equipment parts that
are in touch with explosive
mixture

:

T1: 450

0

C

T2: 300

0

C

T3: 200

0

C

T4: 135

0

C

T5: 100

0

C

T6: 85

0

C

Temperature class
of the gas or vapor
auto ignition

:

T1: > 450

0

C

T2: > 300

0

C

T3: > 200

0

C

T4: > 135

0

C

T5: > 100

0

C

T6: > 85

0

C



Equipment group:
I – underground parts
of mines
II – all other places liable
to be endangered by
explosive atmospheres

Categories for group II
equipment:

1 -

the device assures a

very high protection
level,
- to be operated in
zones 0,1,2

2 -

the device assures a

high protection level,
- to be operated in
zones 1,2

3 -

the device assures a

standard protection
level,
- to be operated in
zone 2

Security level
Gas atmosphere:
- Ga
- Gb
- Gc
Dust atmosphere:
- Da
- Db
- Dc