Adjusting the clamp pad assembly, Adjusting the dark shutter, Adjustment specification – Kodak 4600 User Manual

Page 34

Advertising
background image

SERVICE MANUAL

34

18NOV97 – SM5440-1

Adjusting the CLAMP PAD ASSEMBLY

Warning

Dangerous Voltage

[1] Disconnect the main power.

[2] Do the removal for the LOWER HOUSING

ASSEMBLY.

Important

It is necessary to make a FAN COVER TOOL. See the
Tools section.

[3] Install the FAN COVER TOOL over the FAN area

and the LAMP MODULE. See the Tools section.

[4] Connect the REMOTE CONTROL ASSEMBLY

EC-3 to the REMOTE RECEPTACLE.

Warning

Dangerous Voltage

[5] Connect the main power.

[6] Loosen the NUT on the CLAMP PAD ASSEMBLY.

[7] Energize the REMOTE FOCUS in either direction.

[8] Rotate the SCREW on the CLAMP PAD

ASSEMBLY to adjust the pressure of the
REMOTE FOCUS CLAMP on the CLAMP PAD
ASSEMBLY until the CLAMP PAD ASSEMBLY
does not move.

[9] Release the REMOTE FOCUS.

[10] Tighten the NUT on the CLAMP PAD ASSEMBLY.

[11] Install the AUTO-FOCUS GAUGE TL-1744 in the

MECHANISM GATE. The CLAMP PAD
ASSEMBLY should move forward and backward
using TL-1744. If not, adjust the SCREW on the
CLAMP PAD ASSEMBLY again; the CLAMP PAD
ASSEMBLY adjustment is too tight and not
correct.

Adjustment Specification

The PRESSURE PAD should be aligned with the DARK SHUTTER.

Adjusting the DARK SHUTTER

[1] Do the removal for the LOWER HOUSING.

[2] Insert a thin SLIDE into the GATE MECHANISM; the DARK SHUTTER should open.

[3] Check the the PRESSURE PAD is correctly aligned with the the DARK SHUTTER.

[4] Bend the PRESSURE PAD to adjust the alignment.

A091_4041GA

A091_4041GCA

SCREW

NUT

CLAMP PAD
ASSEMBLY

Advertising
This manual is related to the following products: