AquaPRO VIP50PRO User Manual

Submersible utility pumps, Description, Unpacking

Advertising
background image

General Safety
Information

1. Know the pump application,

limitations, and potential hazards.
Read these rules and the instructions
carefully. Failure to follow them
could cause serious bodily injury
and/or property damage.

Do not use to pump flammable
or explosive fluids such as
gasoline, fuel oil, kerosene,
etc. Do not use in flammable and/or
explosive atmospheres. Pump should
only be used with liquids compatible
with pump component materials. Failure
to follow this warning can result in
personal injury and/or property damage.

2. Make certain that the power source

(electric motor) conforms to the
requirements of the equipment.

Disconnect power before ser-
vicing. If the power disconnect
is out of sight, lock in the open
position and tag it to prevent unexpected
application of power. Failure to do so
could result in fatal electrical shock!

3. Release all pressure within the system

before servicing any component.

4. Drain all liquids from the system

before servicing.

5. Secure the discharge line before

starting the pump. An unsecured
discharge line will whip, possibly
causing personal injury and/or
property damage.

6. Check hoses for weak and worn

condition before each use, making
certain that all connections are
secure.

7. Periodically inspect the pump and

system components. Perform routine
maintenance as required (See Main-
tenance Section).

!

DANGER

!

WARNING

Submersible
Utility Pumps

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could
result in personal injury and/or property damage! Retain instructions for future reference.

Operating Instructions and Replacement Parts List

VIP50PRO

Description

This portable, submersible utility pump is
designed and intended for non-
automatic use in water. The units are
equipped with an 8-ft. 3-prong ground-
ing-type power cord. The shaded-pole
motor is oil filled and sealed for cooler
running and designed to operate under
water. The non-clogging impeller design
eliminates debris from stopping the
pump. The elbow fitting allows
convenient discharge through a garden
hose.

IMPORTANT: THIS PUMP IS NOT
SUITABLE FOR AQUATIC LIFE!

Unpacking

Inspect this unit before it is used.
Occasionally, products are damaged during
shipment. If the pump or components are
damaged, return the unit to the place of
purchase for replacement. Failure to do so
could result in serious injury or death.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.

Danger indicates an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.

Warning indicates a potentially
hazardous situation which, if not avoided,
could result in death or serious injury.

Caution indicates a potentially hazardous
situation which, if not avoided, may
result in minor or moderate injury.

Notice indicates important information,
that if not followed, may cause damage
to equipment.

!

NOTICE

!

CAUTION

!

WARNING

!

DANGER

322700-013 3/06

This utility pump is not constructed to
handle laundry discharge or any other
application which may contain caustic
chemicals and/or foreign materials. Pump
damage could occur if the pump is used in
these applications.

8. Provide a means of pressure relief

for pumps whose discharge line can
be shut-off or obstructed.

9. Personal Safety:

a. Wear safety glasses at all times

when working with pumps.

b. Keep work area clean,

uncluttered and properly lighted;
replace all unused tools and
equipment.

c. Keep visitors at a safe distance

from the work area.

10. When wiring an electrically driven

pump such as this, follow all
electrical and safety codes, as well
as the most recent National
Electrical Code (NEC) and the Occu-
pational Safety and Health Act
(OSHA).

11. This equipment is only for use on

120 volt (single-phase) and is
equipped with an approved 3-con-
ductor cord and 3-prong,
grounding-type plug as shown in
Figure 1.

To reduce the risk of electric shock,
the motor must be securely and
adequately grounded. This can be
accomplished by inserting plug
directly into a properly installed and
grounded 3-prong, grounding-type
receptacle (as shown in Figure 1).

!

CAUTION

© 2006 Aqua Pro Systems

Para ordenar repuestos en EUA,
llame al teléfono 1-877-278-2797

Sírvase darnos la siguiente información
- Número del modelo
- Número de serie

(si tiene)

- Descripción y número de la pieza (tal

como se muestra en la lista de repuestos

Escribanos a la siguiente dirección
Aqua Pro Systems
Attn: Parts Department
101 Production Drive
Harrison, OH 45030 U.S.A.

Instrucciones de funcionamiento y de Instalacion

Requerimientos eléctricos . . . . . . . . . . . . . . . . . .120 voltios, 60 Hz
Motor . . . . . . . . . . . . . . . . . . . .Monofásico, lubricado de por vida
Amperaje máximo del motor . . . . . . .6,2 amperios (1/5 & 1/4 CP)

8,5 amperios (1/2 CP)

Protector térmico . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Automático
Rango de la temperatura del líquido . . . . . . . .4,5-49˚C (40-120˚F)
Posición para el funcionamiento . . . . . . . . . . . . . . . . . . . . .Vertical
Amperaje mínimo del circuito . . . . . . . . . . . . . . . . . . .15 amperios
Peso . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,9 kg (1/5 & 1/4 CP)

3,3 kg (1/2 CP)

Dimensiones (totales) . . . . . . . . . . . . . . . . .9,5 de altura X 6,13 de

diámetro de la base (24,1 X 15,6 cm)

Especificaciones

1

4

3

2

Materiales
Envoltura del motor . . . . .Termoplástico reenforzado con vidrio
Voluta . . . . . . . . . . . . . . . . .Termoplástico reenforzado con vidrio
Impulsor . . . . . . . . . . . . . . .Termoplástico reenforzado con vidrio
Eje . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Acero inoxidable 416
Sellos y anillo en O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Buna N
Cordón eléctrico . . . . . . . . . . . . . . . . . . . . . . . . . . .con 3 terminales
Desagüe
Codo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3,18 cm NPT (1,25 ")
Profundidad de funcionamiento
Profundidad mínima . . . . . . . . . . . . . . . . . . . . . . . . . 0,32 cm (1/8")

No. de
Ref.

Descripción

VIP50PRO

Ctd

1

Ensamblaje de la bomba

57711-001

1

2

Ensamblaje de la codón eléctrico

31006-005

1

3

Ensamblaje de la codo

62002-001

1

4

Ensamblaje de la Impulsor

62001-001

1

See Warranty on page 4 for important information about commercial use of this product.

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

Garantía limitada

Durante un (1) año a partir de la fecha de compra, Aqua Pro (“Wayne Water Systems”) reparará o reemplazará, según lo decida,
para el comprador original, cualquier pieza o piezas de sus Bombas para cloacas o Bombas de agua (el “Producto”) que después de un
examen sea(n) hallada(s) por Aqua Pro como defectuosa(s) en su material o mano de obra. Sírvase llamar a Aqua Pro (877-278-2797) para
obtener instrucciones o consulte a su distribuidor. Esté listo para proporcionar el número de modelo cuando ejerza el derecho a esta
garantía. Todos los gastos de transporte de los productos o piezas enviadas para su reparación o reemplazo serán a cargo del comprador.

Esta Garantía Limitada no cubre productos que estén dañados debido a accidentes, abuso, uso indebido, negligencia, instalación
incorrecta, mantenimiento inadecuado, o no hacerlo funcionar según las instrucciones escritas de Aqua Pro.

NO HAY OTRAS GARANTÍAS EXPRESAS. LAS GARANTÍAS IMPLÍCITAS, INCLUYENDO AQUELLAS DE COMERCIABILDAD
E IDONEIDAD PARA UN USO ESPECÍFICO, SON LIMITADAS A UN AÑO A PARTIR DE LA FECHA DE COMPRA. ESTE ES EL ÚNICO
RECURSO Y SE EXCLUYE CUALQUIER RESPONSABILIDAD POR TODO DAÑO DIRECTO O CONSECUENTE O POR CUALQUIER GASTO.

Algunos estados no permiten limitaciones sobre la duración de las garantías implícitas, o no permiten la exclusión ni la limitación de daños
incidentales o consecuentes, por lo tanto es posible que las limitaciones anteriores no se apliquen en su caso. Esta garantía limitada le
proporciona derechos legales específicos, y también puede tener otros derechos que varían de un estado a otro.

En ningún caso, ya sea por incumplimiento del contrato de garantía, incumplimiento (incluyendo negligencia) u otro, Aqua Pro o sus
proveedores serán responsables de ningún daño especial, consecuente, incidental o penal, incluyendo, pero sin limitarse a pérdida de
ganancias, pérdida de uso del producto o cualquier equipo asociado, daños al equipo asociado, costo de capital, costo de productos sustitutos,
instalaciones, de servicio o reemplazo de fuente de energía, costos de inutilidad, o reclamos de clientes del comprador por dichos daños.

Usted DEBE conservar su recibo de compra junto con este formulario. En caso de tener que ejercer un reclamo de garantía, DEBE enviar
una COPIA del recibo de compra junto al material o correspondencia. Sírvase llamar a Aqua Pro (877-278-2797) para obtener
autorizaciones e instrucciones de devolución.

NO ENVÍE POR CORREO ESTE FORMULARIO A AQUA PRO. Utilice este formulario para mantener sus registros.

MODELO NO. _____________________ NO. DE SERIE ___________________________ FECHA DE INSTALACIÓN ______________________

SUJETE SU RECIBO AQUÍ

8 Sp

Figure 1

TEST

RESET

Advertising