Series 2 and 3 devices – Adcon A720 User Manual

Page 30

Advertising
background image

CHAPTER 4

Performing Advanced Functions

30

B – sends a broadcast frame and displays all the answers.

Series 2 and 3 devices

Note: With Series 2 and 3 devices, typing the command by itself is

a GET command, while typing the command with parame-
ters or variables is a SET command.

C

OMMAND

CMDS

APPLIES

TO

A720, A720B, A723

D

ESCRIPTION

Returns a list of supported commands.

P

ARAMETERS

None.

REMARKS

GET only.

R

ETURNS

A list of strings separated by spaces.

REMOTE

No.

E

XAMPLE

CMDS
193 CMDS CMDS ID PMP RSSI TIME FREQ DEV DEL REPL
SLOT DATA INFO RX TX ERA 0
#

C

OMMAND

TIME

APPLIES

TO

A720B, A723

D

ESCRIPTION

Sets/returns the real time clock.

P

ARAMETERS

The actual time, or none in the GET version.

R

ETURNS

The actual time as dd/mm/yyyy hh:mm:ss.

REMARKS

GET/SET.

REMOTE

No.

E

XAMPLES

TIME 12/12/1998 22:10:10
193 TIME 0
#

TIME
193 TIME 12/12/1998 22:10:10 0
#

Advertising
This manual is related to the following products: