ADTRAN FT1 DP User Manual

Hdsl quick installation guide, For adtran ft1 dp and fnid, Option settings (arrows indicate default settings)

Advertising
background image

1

Section 61242.047L2-13, Issue 1

61242.047L2-13A

HDSL Quick Installation Guide

for ADTRAN FT1 DP and FNID

Three eight-position switch packs (SW1, 2, 4) and two four-position switch packs (SW3, 5) are used to configure
FT1 DP mode of operation as listed in the table below. Refer to ADTRAN Installation/Maintenance practices for more
information.

PRACTICES

Description

Selects between alternating and contiguous DS0 channels.

When this switch is closed, the unit automatically detects the line code as B8ZS or
AMI.

When SW1-2 is open, SW1-3 open selects B8ZS line code, while SW1-3 closed
selects AMI.

When this switch is closed, Auto Frame Mode detection is enabled and the unit
selects between SF and ESF modes automatically. When open, SW1-5 manually
selects the framing mode.

When SW1-4 is open, SW1-5 closed selects SF. SW1-5 open selects ESF.

This switch is used to enable or disable latching loopbacks.

SW1-7 is used to enable or disable automatic loopback timeout.

Sets the data pattern sent to the customer upon FNID network loopback.

The DS1 signal level delivered to the customer through the FNID may be selected
as one of four values: 0, -7.5, -15, or -22.5 dB.

When SW3-1 is closed, auto idle code detection is enabled and the unit selects
between 7F (Hex) and FF (Hex).

When SW3-1 is open and SW3-2 is closed, selects FF (Hex). When SW3-2 is open,
selects 7F (Hex).

This switch enables or disables A/B signaling for Channel 1-8 of the selected FT1
channels.

This switch enables or disables A/B signaling for Channels 9-12 of the selected FT1
channels.

Switch

Function

SW1-1 ............. Channel Select
Closed ............. Alternate
Open ............... Contiguous

SW1-2 ............. Auto Code Detect
Closed ............. Auto
Open ............... Manual

SW1-3 ............. Manual Code Select
Closed ............. AMI
Open ............... B8ZS

SW1-4 ............. Auto Frame Detect
Closed ............. Auto
Open ............... Manual

SW1-5 ............. Framing
Closed ............. Superframe Format (SF)
Open ............... Extended Superframe Format (ESF)

SW1-6 ............. Latching Loopback
Closed ............. Enabled
Open ............... Disabled

SW1-7 ............. Loopback Timeout
Closed ............. 20 Minutes
Open ............... None

SW1-8 ............. Loopback Keep Alive
Closed ............. AIS
Open ............... All 1s, framed

SW2-8, 2-7 ...... DS1 Transmit Level
Open, Open .... 0 dB
Open, Closed .. -7.5 dB
Closed, Open .. -15 dB
Closed, Closed -22.5 dB

SW3-1 ............. Idle Code Detect
Closed ............. Auto
Open ............... Manual

SW 3-2 ............ Idle Code
Closed ............. FF
Open ............... 7F

SW4-1-SW4-8 Channels 1-8 A/B Signaling
Closed ............. Enabled
Open ............... Disabled

SW5-1-SW5-5 Channels 9-12 A/B Signaling
Closed ............. Enabled
Open ............... Disabled

FNID
SW1, SW2
20 mA, 60 mA
Off, On

Option Settings

(arrows indicate default settings)

POWER

LOCAL SPAN

SW1

DS1 SEALING CURRENT

SW2

20MA
60MA

OFF
ON

Powered

by -48

VDC

Powered

by span

current

Sealing current disabled

Sealing current enabled

20 mA sealing current select

Indicates default setting

Advertising