bearings because this could damage the motor and
cause a re t u rn service call.

1.TURN THE POWER OFF
2 .
Remove the cover from the motor and disconnect

the electrical supply leads from the terminal board.

Then remove the electrical cable
or conduit from the end frame.

3 . Remove the motor from the

pump unit.

4 . Mark the brackets and frame

of the motor, to assure corre c t
alignment of these parts when reassembling them.

5 . Remove the rotor and shaft from the frame of the

m o t o r, following these steps as necessary :
a ) Take out the thru-bolts that secure the brackets

to the frame.

b )Remove the bracket opposite the shaft by

placing a screwdriver blade in the notches of
this bracket and tapping the handle of the

s c re w d r i v e r.

c ) Remove the locking collar screws and washers if

their use prevents removal of the rotor assembly

f rom the shaft end bracket.

d ) C a refully pull the shaft/rotor assembly out of the

shell or stator toward the shaft extension end.

e ) Be careful not to lose the washer and bearing

load spring that is positioned in the bottom of the
bearing bore of the bracket opposite the shaft
extension. Be sure to replace this spring during
re a s s e m b l y.

2 5

MOTOR TROUBLESHOOTING