Installation Procedures: 12" and 15" Panels

52

VG-Series Modero Touch Panels

9.

Reconnect the terminal RJ-45, Ethernet, USB, and any optional audio/video wiring to their respective
locations (outside the conduit box) on either the NXA-AVB/RGB Breakout Box, Ethernet port, or
NetLinx Master.

10.

Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.

Installing the NXD into drywall using Expansion Clips

Expansion clips are mounted through the four oval holes located at the top and bottom of the panel. As the
screw is tightened, the clip bends toward the insertion hole and into the wall. This bending creates a "grip" on
the wall by either pressing onto the wall or by securing the drywall between the housing and the drywall clip.

The most important thing to remember when mounting the NXD is that the outer frame (Mounting Tabs) must
be installed flush against the mounting surface.



It is recommended that you cutout the surface slightly smaller than what is outlined in the
installation drawings so that you can make any necessary cutout adjustments.

1.

Prepare the area by removing any screws or nails from the drywall before beginning the cutout process.

2.

Cut out the surface for the 12-inch Wall Mount using the dimensions shown in FIG. 40 and for the 15-
inch Wall Mount
using the dimensions shown in FIG. 41. Be sure to cut out the four notches along the
top and bottom areas to accommodate the four drywall expansion clips (provided).

3.

Remove the magnetic faceplate/bezel (A in FIG. 42) from the main NXD unit (B in FIG. 42) by gripping
the faceplate and pulling with gentle outward force.

FIG. 40

NXD-1200VG 12-inch Wall Mount panel dimensions using expansion clips

FRONT BEZEL

CUTOUT

Advertising