Installation Procedures: 17" Panels

77

VG-Series Modero Touch Panels

14.

Follow the procedures outlined within Steps 1 - 5 on page 36 thru page 38 to carefully reinstall the LCD
panel back into the back box housing.

15.

Carefully slide the main unit into the cutout until the Mounting Tabs of the NXD-1700VG unit lie flush
against the wall.

16.

Insert and secure the four #6 screws into their corresponding holes located along the sides of the NXD-
1700VG (using a grounded Phillips-head screwdriver) until the unit is secure and flush against the wall.

17.

Place the magnetic faceplate (A in FIG. 62) back onto the main NXD unit. Make sure to align the
Microphone, Light, and PIR Motion sensor locations to their respective openings on the front
bezel/faceplate.

18.

Reconnect the terminal RJ-45, Ethernet, and any optional audio/video wiring to their respective terminal
locations on either the NXA-AVB/RGB Breakout Box, Ethernet port, or NetLinx Master.

19.

Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.

Installing an NXD into an (optional) Rack Mount Kit (NXA-RK17)

1.

Remove the magnetic faceplate/bezel from the main NXD unit by gripping the faceplate and pulling with
gentle outward force.

2.

Thread the incoming RJ-45, Ethernet, and any optional audio/video wiring (from their terminal locations)
through the opening in the equipment rack. Refer to the Wiring Guidelines for the 1700VG Panels section
on page 78 fo
r pinout descriptions. Leave enough slack to accommodate any re-positioning of the panel.

3.

Connect all data and power wiring connectors to their corresponding locations along the side of the (un-
powered) NXD touch panel.



Verify the terminal end of the power cable is not connected to a power supply before plugging in the

2-pin power connector.

4.

Test the incoming wiring by connecting the panel connections to their terminal locations and applying
power. Verify the panel is receiving power and functioning properly to prevent repetition of the
installation.

5.

Disconnect the terminal end of the power cable from the connected power supply.

6.

Insert the main 17-inch Modero unit into the NXA-RK17 (FIG. 63).

Don’t disconnect the connectors from the touch panel. The unit must be installed with
the attached connectors before being inserted into the solid surface.

Don’t disconnect the connectors from the touch panel. The unit must be installed with
the attached connectors before being inserted into the equipment rack.