Manual rebuild - batch mode, Using a pre-loaded scsi drive "as-is – Toshiba Magnia 560S User Manual

Page 136

Advertising
background image

Using a Pre-loaded SCSI Drive "As-is"

118

MegaRAID BIOS Configuration Utility

Manual Rebuild - Batch Mode

Perform these steps to manually rebuild more than one drive:

1. Select Rebuild from the MegaRAID Configuration Utility Management Menu.

A device selection window displays the devices connected to the current controller.
The failed drives have FAIL indicators.

2. Press the arrow keys to highlight the drives to be rebuilt.

3. Press the spacebar to select the selected physical drive for rebuild.

4. After selecting the physical drives, press <F10> and select Yes at the confirmation

prompt.

The indicators for the selected drives changes to REBLD. Rebuilding can take some
time, depending on the number of drives you have selected and the drive capacities.

5. When rebuild is complete, press any key to continue.

6. Press <Esc> to display the Management Menu.

Using a Pre-loaded SCSI Drive "As-is"

IMPORTANT: To use a pre-loaded system drive in the manner described here,
you must make it the first logical drive defined (for example: LD1) on the
controller it is connected to. This will make the drive ID 0 LUN 0. If the drive
is not a boot device, the logical drive number is not critical.

You may have a SCSI disk drive that is already loaded with software. The drive may be
a boot disk containing an operating system. You can use the MegaRAID controller as a
SCSI adapter for such a drive by performing the following steps:

1. Connect the SCSI drive to the channel on the MegaRAID controller, with proper

termination and TID settings.

2. Boot the computer and start Configuration Utility by pressing <Ctrl> <M>.

3. Choose Easy Configuration from the Configure menu.

4. Press the cursor keys to select the pre-loaded drive.

5. Press the spacebar.

The pre-loaded drive should now become an array element.

6. Press <Enter>.

You have now declared the pre-loaded drive as a one-disk array. The logical drive
configuration screen displays.

7. Set the Read Policy and Cache Policy on the Advanced Menu.

8. Exit the Advanced menu.

9. Highlight Accept and press <Enter>.

10. Press <Esc> and choose Yes at the Save prompt.