Use the correct descaling agent, Descaling procedure – Philips SENSEO® Sistema de monodosis de café User Manual

Page 15

Advertising
background image

- It prevents malfunctioning

If the descaling procedure is not performed correctly, scale residue remains

behind in the machine. This causes scale to build up more quickly and may

cause permanent and irreparable damage to the machine.
use the correct descaling agent

Only citric acid-based descalers are suitable for descaling the SENSEO

®

machine. This type of descaler descales the appliance without damaging

it. For the correct amount, see under ‘Descaling procedure’ below. Each

descaling mixture can be used only once. After use, the descaling mixture is

no longer active.

We advise you to use a citric acid based descaling agent. Read the

instructions on the package of the descaling agent.
Never use a descaling agent based on mineral acids such as sulphuric

acid, hydrochloric acid, sulphamic acid and acetic acid (e.g. vinegar). These

descaling agents may damage your SENSEO

®

coffee machine.

Descaling procedure

1

Mix 50 grams of citric acid with 1 litre of water in a measuring jug.

Stir until the powder is completely dissolved.

2

Fill the water reservoir up to the MAX indication with the descaler

mixture. Then put the water reservoir back into the coffee machine.

Note: Not all SENSEO

®

machine types have a water reservoir with a capacity

of 1 litre. If you have a SENSEO

®

machine with a smaller water reservoir,

repeat steps 2 to 6 with the remainder of the mixture without filling the water

reservoir up to the MAX indication.

3

Press on/off button I.

The machine is ready for use when the indicator light burns continuously.

4

Place the 1-cup holder ° with a used coffee pod in it in the coffee

machine. Close the lid and make sure it is properly locked.

Note: Always put a used coffee pod in the pod holder when you descale the

machine. This pod serves as a ‘filter’ to prevent the sieve or hole in the pod

holder from getting clogged with scale residue.

5

Put a bowl with a capacity of at least 1500ml under the spout to

collect the descaling mixture.

6

Press the 2-cup button °° and let the machine operate. Repeat

this until the water reservoir is empty.

Never interrupt the descaling process!

7

Repeat steps 1 to 6. Replace the used pod with another used pod to

filter out the scale residue.

Note: To descale properly, you have to use 2 litres of descaling mixture.

Never descale the SENSEO

®

coffee machine with the lid open. Make

sure the lid is properly locked.

EnglisH