Bryant Legecy Line-RNC Non-Programmable T1-NAC User Manual

Bryant Control panel

Advertising
background image

T1--NAC

T1--NHP

LEGACY LINE--RNC

NON--PROGRAMMABLE THERMOSTAT

Installation Instructions

Designed and Assembled

in the USA.

US patents: US20060165149 A1, USD578026 SI, US6205041 B1

A07110

Legacy Line---RNC Non---Programmable Thermostat

NOTE: Read the entire instruction manual before starting the
installation.

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . .

INSTALLATION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 1 — Thermostat Location

2

. . . . . . . . . . . . . . . . . . . . . . . .

Step 2— Install Thermostat

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 3 — Set Thermostat Configuration

2

. . . . . . . . . . . . . . . . .

Step 4 — Thermostat Operation

3

. . . . . . . . . . . . . . . . . . . . . . . .

Step 5 — Check Thermostat Operation

3

. . . . . . . . . . . . . . . . . .

WIRING DIAGRAMS

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,

or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury, or property

damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified
installer or agency muse use factory--authorized kits or accessories

when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Have a fire extinguisher available. Read these

instructions thoroughly and follow all warnings or cautions
included in literature and attached to the unit. Consult local

building codes and the current editions of the National Electrical

Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical

Code CSA C22.1.

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the unit and in the instructions or

manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and

CAUTION. These words are used with the safety--alert symbol.

DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies a hazard

which could result in personal injury or death. CAUTION is used
to identify unsafe practices which may result in minor personal

injury or product and property damage. NOTE is used to highlight

suggestions which will result in enhanced installation, reliability, or
operation.

INTRODUCTION

The Legacy Line--RNC Series thermostat is an electronic 24VAC,
non--programmable, manual changeover wall mount thermostat.

This thermostat uses a single setpoint to maintain and control room
temperature in both the heating and air conditioning modes. The

thermostat is designed to maintain +/-- 2_F accuracy. No batteries

are required; temperature, fan, mode, and installer configuration
settings are preserved with power off.

INSTALLATION CONSIDERATIONS

Air Conditioner Model

T1--NAC, Legacy Line--RNC Series Model air conditioner
thermostat, may be wired with or without connecting a common

wire between the indoor equipment and the thermostat. However, it
is recommended to use a common wire whenever possible.

Without a common wire this thermostat becomes “power stealing.”

This means it will need to steal a small amount of power from the
equipment to which it is connected.
NOTE: Not all HVAC equipment is compatible with power
stealing type thermostats. All Bryant equipment is directly
compatible with this thermostat except the Thermostat Conversion
Kit, Part #TSTATXXCNV10. For all non--Bryant equipment,
consult the system equipment Installation Instructions before
applying this thermostat in a power stealing manner.

Heat Pump Model

T1--NHP, Legacy Line--RNC Series Model heat pump thermostat,
is compatible with all Bryant heat pump systems. It is NOT power

stealing and MUST have both the R and C terminals connected to

operate properly. This thermostat uses a green LED to indicate
auxiliary heat and emergency heat operation.

Advertising