Alarm connector

Max. wire diameter AWG 22-28 for both stranded and solid

Default relay position n.o. (normally open), no alarm

Alarm output relay switching capability: Max voltage 30VAC or
+40VDC. Max 0.5 A continuous, 10VA.

Alarm in: TTL logic, +5V nominal, +40VDC max, DC coupled with
22k

Ω pull-up to +3.3V

Alarm in: configurable as active low or active high

Max. 42V allowed between camera ground and each of the relay pins.

Lens mounting

The camera accepts CS-mount lenses. C-mount lenses can be mounted
using the lens adapter ring. DC-iris lenses are recommended for the best
picture performance. The camera automatically detects the type of lens
used and optimizes performance accordingly. A spare male lens connector
is provided.

Caution

To avoid damaging the CCD sensor when using a C-mount lens,
make sure the supplied lens adapter ring is mounted onto the
camera before mounting the lens.
Lenses weighing more than 0.5 kg (1.1lbs) must be separately
supported.

Alarm

Pin 1

Pin 4

Pin

Alarm socket

1

Alarm in Ground

2

Alarm in

3

Relay out contact 1

4

Relay out contact 2