3.2.1 Priming a monitor system
Priming describes the process of detecting and supressing feedback frequencies.

After placing and leveling your mics and monitors (incl. power amps), you should

crank up the aux send controls of your mixer.
Now, activate the FBQ feedback detection system by pressing the FBQ switch (3).

The slide control LEDs (9) will turn dark. Then, increase the amplification on your

mixer by using the aux send master control until you notice feedback starting to

occur. Feedback frequencies will now be easily visible through intensive lighting

of the relevant LEDs.
Pull down the slide controls whose LEDs are lit until the feedback subsides.

Repeat this procedure to weed out other possible feedback frequencies.

After having adjusted all critical frequencies, when you crank up the aux send

master control, you will be able to hear only the initial multi-frequency feedback.

Your monitors have reached their maximum volume.
Leave all other faders in the middle position as long as no need for frequency

correction occurs (e.g. measuring with a real-time analyzer). Set the desired

stage volume, and you will have a tremendous amount of headroom available

to you, without creating audible feedback.

3.3 Using the ULTRAGRAPH PRO in the studio

Additional applications await the ULTRAGRAPH PRO models in the studio.

No limits stand in the way of your imagination. Here are just a few examples

of possible uses:

EQing your studio monitors:
You can conduct a graphic equalization of your monitors. Besides, you can supress

narrow-band room resonance. An analyzer, for example the analyzer integrated

into our digital equalizer ULTRACURVE PRO DEQ2496, can help you when you are

looking for room resonance and a linear frequency response.

General sound processing:
Equalizers can be used to process both single-channel and master signals.

To process single-channel signals, you should connect the ULTRAGRAPH PRO

via the channel inserts on your mixer. To control several signals with your

ULTRAGRAPH PRO, use either subgroup or main mix inserts. Nowadays,

the overall sound of a mix is often “tweaked” with equalizers. Often, a mix is not

uniform, that is, frequency ranges are either too prominent or not prominent at

all. A graphic equalizer lets you find a fitting ratio between the intensity of these

various frequency ranges in order to achieve a homegenous sound.

3.4 Special sound effects

In recording studios as well as stage or radio plays, the ULTRAGRAPH PRO will be

your valuable sound tool for modifying the sound of voices (e.g. telephone voice)

or to filter instruments so that they fit in an existing mix.
The tables on the separate add-on sheet give you an idea of specific frequencies

and their acoustic significance, and suggest some possible uses for your

ULTRAGRAPH PRO.

4. Installation

4.1 Rack mounting

The FBQ1502 requires one height unit (1 HU) for mounting in a 19" rack,

the FBQ3102 two height units, and the FBQ6200 three height units. Please allow

at least an additional 4" of space for the connectors on the back panel.
Be sure that there is enough space around the unit for cooling and please do

not place your ULTRAGRAPH PRO on high-temperature devices such as power

amplifiers etc. to avoid overheating.
For rack mounting, please use M6 metal nuts and bolts.

4.2 Audio connections

You will need many different cables for the various applications. The following

illustrations show how these cables should be laid out. Please use exclusively

high-grade cabels.
The ULTRAGRAPH PRO is installed with electronically servo-balanced inputs and

outputs to avoid hum noise problems.
You can, of course, also connect unbalanced devices to the balanced inputs/

outputs. Either use mono plugs, or connect the ring and sleeve of stereo plugs

(bridge pin 1 and pin 3 when using XLR connectors).

Please ensure that only qualified personnel install and operate the
ULTRAGRAPH PRO. During installation and operation the user must
have sufficient electrical contact to earth. Electrostatic charges might
affect the operation of the unit.

output

For unbalanced use, pin 1 and pin 3

have to be bridged

1 = ground/shield

2 = hot (+ve)

3 = cold (-ve)

input

1

2

3

1

2

3

Balanced use with XLR connectors

Fig. 4.1: XLR connectors

Advertising