u

Compliance with the ambient temperatures

indicated is required, otherwise the cooling

performance is reduced.

Climate

rating

for ambient temperatures of

SN

10 °C to 32 °C

N

16 °C to 32 °C

ST

16 °C to 38 °C

T

16 °C to 43 °C

1.3 Conformity

The refrigerant circuit is tested for leakage. The appliance

complies with the relevant safety regulations and EC Directives

2006/95/EC, 2004/108/EC, 2009/125/EC and 2010/30/EU.
Note for test institutions:

Tests are to be carried out according to the applicable

standards and guidelines.

Preparation and testing of the appliances must be carried

out taking the manufacturer's loading plans and the

notes in the operating manual into account.

1.4 Installation dimensions

Fig. 2

a

b

c

c'

d

e

e'

g

h

T1710

554 550 561 590 1125 623 652 610 850

T1810

601 597 612 640 1175 628 654 610 850

TP1710

601 597 612 640 1175

x

628

x

654

x

610

x

850

TP1720

601 597 612 640 1175

x

628

x

654

x

610

x

850

TPesf1710 601 597 595 642 1175

x

608

x

655

x

610

x

850

T1714

601 597 612 640 1175 628 654 610 850

TP1714

601 597 612 640 1175

x

628

x

654

x

610

x

850

TPesf1714 601 597 595 642 1175

x

608

x

655

x

610

x

850

TP1724

601 597 612 640 1175

x

628

x

654

x

610

x

850

TP1410

554 550 561 590 1125

x

623

x

652

x

610

x

850

TP1414

554 550 561 590 1125

x

623

x

652

x

610

x

850

TP1434

554 550 561 590 1125

x

623

x

652

x

610

x

850

T1514

554 550 561 590 1125 623 652 610 850

TP1514

554 550 561 590 1125

x

623

x

652

x

610

x

850

T1700

554 550 561 —

1125 623 —

610 850

T1504

554 550 561 —

1125 623 —

610 850

T(sl)1414 501 497 505 534 1072 620 649 610 850
TP1424

501 497 505 534 1072

x

620

x

649

x

610

x

850

T1410

501 497 505 534 1072 620 649 610 850

T1404

501 497 505 —

1072 620 —

610 850

T1400

501 497 505 —

1072 620 —

610 850

x

For appliances supplied with wall spacers, the measurement

increases by 35 mm (see 4.2) .

1.5 Saving energy

-

Always ensure good ventilation. Do not cover ventilation

openings or grille.

-

Do not place appliance in areas of direct sunlight or next to a

stove, heater or similar object.

-

The energy consumption depends on the installation condi-

tions, e.g. the ambient temperature (see 1.2) .

-

Keep the time the appliance is open to a minimum.

-

The lower the temperature setting, the higher the power

consumption.

-

Store food logically. (see Appliance at a glance).

-

Ensure that all food is well packed and covered for storage.

This will prevent frost from forming.

-

First cool warm food to room temperature before storing it .

-

Defrost frozen food in the refrigerator.*

-

If there is a thick layer of frost in the appliance: defrost the

appliance.*

Accumulated dust increases the energy

consumption:

-

Once a year, dust the refrigerating unit

together with the metal grille of the heat

exchanger at the back of the appliance.

2 General safety information

Danger for the user:

-

This appliance can be used by children of 8

years old and over, and also by persons with

restricted physical, sensory or mental

capacity or lack of experience and knowl-

edge, if they are supervised or have been

instructed on safe use of the appliance and

understand the resulting risks. Children must

not be allowed to play with the appliance.

Cleaning and user maintenance must not be

carried out by children without supervision.

-

When disconnecting the appliance from the

supply, always take hold of the plug. Do not

pull the cable.

-

In the event of a fault pull out the mains plug

or deactivate the fuse.

General safety information

* Depending on model and options