4insertion into a row of kitchen units, 5disposing of packaging, 6connecting the appliance – Liebherr CUPsl 2721 Comfort User Manual

Page 6: Putting into operation, 4 insertion into a row of kitchen units, 5 disposing of packaging, 6 connecting the appliance

Advertising
background image

Fig. 4

u

Follow the order of the positions.

4.4 Insertion into a row of kitchen units

Fig. 5

(1) Stack cabinet

(3) Kitchen cabinet

(2) Appliance

(4) Wall

The appliance can be inserted into a row of kitchen units. To

match the appliance

Fig. 5 (2)

to the height of the row of units,

a suitable stack cabinet

Fig. 5 (1)

can be fitted above the appli-

ance.
In conversions with kitchen cabinets (max depth. 580 mm) the

appliance can be installed directly next to the kitchen cabinet

Fig. 5 (3)

. The appliance door will project 34 mm at the sides

and 50 mm in the centre in relation to the kitchen cabinet front.

This means that the appliance door can be freely opened and

closed.
Ventilation requirements:

-

At the back of the stack cabinet there has to be a ventilation

duct of at least 50 mm depth throughout the width of the

stack cabinet.

-

The ventilation space under the ceiling has to be at least

300 cm

2

.

-

the larger the ventilation space, the more energy-saving the

appliance is in operation.

If the appliance is installed with the hinges next to a wall

Fig. 5 (4)

, the distance between appliance and wall has to be at

least 40 mm. This corresponds to the projection of the handle

when the door is open.

4.5 Disposing of packaging

WARNING

Danger of suffocation due to packing material and plastic film!

u

Do not allow children to play with packing material.

The packaging is made of recyclable materials:

-

corrugated board/cardboard

-

expanded polystyrene parts

-

polythene bags and sheets

-

polypropylene straps

-

nailed wooden frame with polyethylene panel*

u

Take the packaging material to an official collecting point.

4.6 Connecting the appliance

NOTICE

Risk of damage to the electronic control system!

u

Do not use stand-alone inverters (conversion of d.c. to a.c./

three-phase) or energy saving plugs.

WARNING

Fire and overheating hazard!

u

Do not use extension cables or multiple socket outlets.

The type of current (alternating current) and voltage at the

installation site have to conform with the data on the type plate

(see Appliance at a glance).
The socket must be properly earthed and fused. The tripping

current for the fuse must be between 10 A and 16 A.
The socket must be easily accessible so that the appliance can

be quickly disconnected from the supply in an emergency. It

must be outside the area of the rear of the appliance.

u

Check the electrical connection.

u

Plug in the power plug.

Putting into operation

6

* Depending on model and options

Advertising
This manual is related to the following products: