Kastor CC 50 Control panel User Manual

Instructions for use cc 50, Settings

Advertising
background image

INSTRUCTIONS FOR USE

CC 50

3

1

2

5

6

7





4

Functions.

1 = lighting. 2 = on/off. 3 = temperature setting. 4 = time setting. 5 = reduce temperature/time. 6 = increase temperature/time. 7 = display.

Lighting.

Lights automatically when the facility starts and switches off automatically when the facility shuts down. You can also switch the lighting on or off manually by pressing
LIGHT.

Main power switch.

To be changed more than once: At the bottom of the relay box, the DI / DU / VU unit and the smaller types of steam generators is a main power switch that disconnects
the heater entirely from the electrical supply. This main switch should only be used if the sauna will not be used for a longer period, such as several weeks. To be changed
more than once: The memory function must be reset each time the power is interrupted.
The thermometer in the sauna/steam bath should be placed at such a height that the temperature corresponds exactly to the numbers in the panel of the CC 50.

SETTINGS

CC 50, all models

Setting the bathing temperature.

Press TEMP – the previous temperature is displayed. Use the up and down arrows (Ч Ш) to change the temperature.

Manual on/off.

Press ON to switch the facility on. Press OFF to switch it off. (The LED goes out). If you forget to switch off the generator manually, it switches off automatically after 3 or
12 hours - depending on the type of control panel.

Timer settings.

(The sauna must be switched off)
Press TIME
(the hour digits blink) – set the number of hours until you want to use the sauna using the up and down arrows (Ч Ш).
Press TIME (the minute digits blink) – set the number of minutes until you want to use the sauna using the up and down arrows (Ч Ш).
(Important: The hour or minute digits must be blinking before you press ON).
Press ON – the on time is activated and a red LED blinks until the sauna automatically starts after the pre-set time. The heater switches off automatically after 3 or 12
hours – depending on the type of control panel.
You can switch off the sauna manually at any time by pressing OFF.

Code lock to prevent settings from being changed.

First program as above, then wait at least 20 seconds. Press on the down arrow (

Ø), hold it down and press TEMP and TIME at the same time. The code lock, which

prevents

all changing of settings, is now activated. To return to unlocked mode, press the down arrow (Ø), hold it down and press OFF at the same time.

Code lock that only prevents changing of the temperature setting.

First program the temperature as above, then wait at least 20 seconds. Press TIME, hold it down and press TEMP and LIGHT at the same time. The code lock, which
prevents changing of the

temperature settings, is now activated. To return to unlocked mode, press the down arrow (Ø), hold it down and press OFF at the same time.

Installation

The box is splash-proof. It may be installed in compliance with local electricity regulations, either in the sauna chamber or outside the chamber. If the box is to be
installed in the sauna chamber in Finland, the distance to the sauna oven must be at least 0.5 metres, while the distance to the floor must not exceed 1.0 metres
(SFS 600-7-703 Region 2).

Remote control.

The heater can be remote-controlled using an impulse switch connected parallel to the On/Off switch. Connect the remote control to the CC control panel
between terminals 19 and 20. Additionally, an indicator lamp may be wired to the system to indicate when the heater is on. The 12VDC lamp is connected
between terminals 19 and 21.