PowerBridge LP3D User Manual

Step 1, Tools for installation, Location - wall cutout

Advertising
background image

THIS PRODUCT IS NOT TO BE INSTALLED, DIRECT WIRED, OR BRANCHED TO THE BUILDING ELECTRICAL CIRCUIT/WIRING SYSTEM !

DO NOT MODIFY OR ALTER ANY PORTION OF THE COMPONENTS OF THE FACTORY ASSEMBLED APPLIANCE


Do not install this product near water, example, near a sink, tub, shower, swimming pool or laundry area.
Manufacturer is not liable for damages due to improper installation
methods not followed herein.
This product does not have built-in electronic circuitry for surge protection or A/C filtering.
It is recommended that this product be connected to a quality surge-protector/power conditioner for equipment protection.

Disclaimer.

HD-Products, LLC, the Manufacturer, it's agents, suppliers, and affiliates, shall not be liable for any damages, not limited to; misuse, acts of nature,

verbal and written expression and improper installation. Improper installation is determined such to include, not limited to, non-code compliant installation, product
modifications, alterations, adjustments, and substitutions of components or materials.
Limited 2-year Warranty from Manufactures Defects: The LP3D has a Limited Two Year product warranty against manufacturer's defects.
If you have any questions or experience any problems with this product, please contact HD-Products Customer Service

.

Step 1

Location - Wall Cutout

PowerOUT - Determine TV wall mount bracket location.
Align between wall framing studs.
Use stud finder to determine in-wall obstructions between
framing both VERTICALLY and HORIZONTALLY.
Install in any direction, right/left, horizontal or vertical below,
above, next to TV wall bracket.

PowerIN - Usually located behind or near AV equipment.
Longer in-wall PowerWire can be installed to located up to 75’ from TV
Install within 60” from an existing power outlet or power-surge device.

Use supplied template sheet to mark area to cut out from drywall.
Use a level to maintain proper alignment.
Carefully use drywall saw to cut along outside of line.

Horizontal
or Vertical

Do not exceed more
than 60” apart from
existing outlet or
surge-protection unit

PowerOUT

PowerIN

HD-Products, LLC., intent to make this manual accurate and complete. However, HD- Products, LLC., makes no claim that the information contained herein covers all details, conditions, or
variations. Nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change
without notice or obligation of any kind. HD-Products, LLC., makes no representation of warranty, expressed or implied, regarding the information contained herein.

ETL LISTED

CONFORMS TO

UL STD 514C

CERTIFIED TO

CAN/CSA STD C22.2 NO.42.1

3183743

HD-Products, LLC. PowerBridge Solution 3869 Norwood Dr. Littleton, CO 80125 USA

Customer Service: Toll Free- 855.755.9838 [email protected] www.PowerBridgeSolution.com

Part No. 44-12P 2012 All Rights Reserved Patent Pending

|

PowerBridge can only be installed

within standard construction walls.

Only attempt installation within

2x4 or 2x6 wood/metal stud

framed wall.

!

!

Ultra Low Profile In-Wall System

If insulation exists, remove or push
completely away from the openings
to allow flush mounting properly.

LEVEL

!

Solution

th

IN-WALL

Tools for Installation

Not Included

Stud Finder

Flat-Blade

Drywall Saw

Kit Includes:

1- Dual Recessed PowerOUT Panel
1- PowerIN Wall Plate with in-wall wiring box

PowerOUT Panel

PowerIN Wall Panel

Level

72” PowerConnect Cord.

72” In-Wall PowerWire

(ROMEX )

Low Profile Recessed In-Wall Kit

Model #LP3D

Power Extension Cable Management

CABLE

POWER

LP3

D

Advertising
Table of contents