PHCC Pro Series S5 - S5 Series Sump Pump User Manual

Specifications, Important safety instructions and warnings

Advertising
background image

Model

Discharge

Amps

Max Solid

Max

GPM / GPH

No.

HP

Volts

Diameter

@ 10

Ј

Handling

Head

@ 10

Ј

S3033

1

/

3

115

1

1

/

2

Љ

4.0

7

/

8

Љ

30

Ј

50

3000

S3050

1

/

2

115

2

Љ

4.3

7

/

8

Љ

33

Ј

65

3900

S3100

1

115

2

Љ

11.5

1

3

/

4

Љ

52

Ј

92

5520

S5033

1

/

3

115

1

1

/

2

Љ

4.0

1

1

/

2

Љ

26

Ј

59

3540

S5050

1

/

2

115

2

Љ

6.8

1

3

/

4

Љ

36

Ј

83

4980

E7040

4

/

10

115

2

Љ

6.3

2

Љ

22

Ј

74

4440

E7055

1

/

2

115

2

Љ

7.0

2

Љ

23

Ј

89

5340

E7100

1

115

2

Љ

12.8

2

Љ

23

Ј

114 6840

Specifications

S5 Series

Dewatering Sump Pumps

5 Year Warranty

E7 Series

Sewage Pumps

3 Year Warranty

PHCC Pro Series

Sump Pumps

Instruction Manual

& Safety Warnings

Important Safety Instructions and Warnings

SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and
OPERATING INSTRUCTIONS for the PHCC Pro Series pumps. You will need to refer to it
before attempting any installation or maintenance.
ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property
damage, serious injury, or death.

ALWAYS disconnect the pump from the power source before servicing or making

adjustments.

NEVER handle the pump or motor with wet hands or when standing on a wet or damp

surface while the pump is plugged into the power source.

MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump is

wired with a 3-prong grounded plug. To reduce the risk of electric shock, be certain
that it is only connected to a properly grounded, 3-prong receptacle (preferably with
ground fault circuit interrupt). If you have a 2-prong receptacle, have a licensed
electrician replace it with a 3-prong receptacle according to local codes and ordinances.

NEVER bypass grounding wires or remove the ground prong from the plug.

DO NOT use an extension cord. The electrical outlet should be within the length of the

pump’s power cord, and at least 4 feet above the floor level to minimize potential
hazards from flood conditions.

DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals.

Avoid kinking the cord.

MAKE SURE the supply circuit has a fuse or circuit breaker rated to handle the power

requirements noted on the nameplate of the pump.

DO NOT remove the power supply cord and strain relief or connect the pump directly to

the conduit.

NEVER install the pump in locations classified as hazardous in accordance with the

National Electrical Code, ANSI/NFPA 70.

ALWAYS install the pump in accordance with the National Electric Code and all

applicable local codes and ordinances. All wiring should be performed by a licensed
electrician.

DO NOT use the power cord or strain relief to carry the pump. Use the pump handle.

DO NOT expose the control unit to rain or snow.

DO NOT operate the pump or control unit if it has been damaged in any way.

DO drill an air bleed hole in the discharge pipe when a check valve is used. Drill

the hole angled toward the bottom of the sump to avoid splashing water outside
the sump pit. If a hole is not drilled above the pump, an air lock may prevent the
pump from operating. The hole must be drilled above the water line but below the
check valve. The optimum size of the hole is different for different pumps. Drill a
1/80 (3.2mm) hole in the discharge pipe for the S3 Series and S5 Series pumps.
Drill a 3/16” (4.76mm) hole in the discharge pipe for the E7 Series pumps.

DO NOT use sump pumps in pits handling raw sewage, salt water, or hazardous liquids.

S2, S3 & S5 Series pumps are not designed for this purpose. E7 Series pumps are
sewage pumps.

DO NOT disassemble the pump or control unit. When service is required, contact

Glentronics technical support at 800-991-0466, option 3. Return the product to the
manufacturer for any repairs at the following address:

Glentronics, Inc.

645 Heathrow Drive, Lincolnshire, IL 60069

ƽ CAUTION

ƽ WARNING

S3 Series

Dewatering Sump Pumps

3 Year Warranty

Risk of electric shock. To reduce this risk, observe the
following precautions
.

To reduce the risk of hazards that can cause injury or
property damage, observe the following precautions.

1

The

Dual Float

Deluxe

Dual Float

Controller

Advertising
This manual is related to the following products: