Status Lights

The AEM Temperature gauge has two status lights, see Figure 4. The status light on
the left will turn on solid if the temperature is less than 100°F (40°C). The status light on
the right will flash if the temperature exceeds 300°F (148°C). Both status lights will
flash if the sensor is disconnected. The needle will point straight downward if the
temperature exceeds 300°F (148°C) or the sensor is disconnected. See Table 1 for a
description of the conditions.




Status Light

Condition

Corrective Action

Left on Solid

Temperature below 100°F (40°C)

--

Right Flashing

Temperature above 300°F (148°C)

--

Both Flashing

Sensor Disconnected/Wires

Shorted

Check wiring


Figure 4. Backlighting Adjustment

Table 1. Status Light Conditions

Figure 4. Illuminated Status Lights

ACCESS
PORT

Left
Status
Light

Right
Status
Light