AEM 30-5140M Analog Oil Transmission Water Temperature Metric Gauge User Manual

Page 5

Advertising
background image

Page 5

Analog Output

The analog output from the AEM Temperature gauge is a linear dc voltage signal that
varies from 0.5 Vdc at 100°F (40°C) to 4.5 Vdc at 300°F (148°C) over the operating
range of the gauge. The signal is used for sending information to a data logger or an
engine management system like the AEM EMS or F/IC. The transfer function for
temperature in degrees Fahrenheit is listed below.

Temperature (Fahrenheit) = 50 x Voltage + 75

The transfer function for temperature in degrees Celsius is listed below.

Temperature (Celsius) = 27 x Voltage + 26.5

A list of output voltages and corresponding temperatures is shown below in Table 1.

Voltage

Temperature

0.50

100 degF

40 degC

0.75

113 degF

47 degC

1.00

125 degF

54 degC

1.25

138 degF

60 degC

1.50

150 degF

67 degC

1.75

163 degF

74 degC

2.00

175 degF

81 degC

2.25

188 degF

87 degC

2.50

200 degF

94 degC

2.75

213 degF

101 degC

3.00

225 degF

108 degC

3.25

238 degF

114 degC

3.50

250 degF

121 degC

3.75

263 degF

128 degC

4.00

275 degF

135 degC

4.25

288 degF

141 degC

4.50

300 degF

148 degC




Connector Pinouts

The pinouts for the 3-pin sensor harness and 8-pin power harness are provided

below in Figure 6.



Figure 6. Harness Pinouts

Table 1. Analog Calibrations