Step-by-step wiring diagrams, Rc g a – 2GIG CT100 User Manual

Page 13

Advertising
background image

12

PG

13

Step-by-step wiring diagrams

W

IR

ES

2 Wire Heat GAS MILLIVOLT or 24VAC system

STEP 1 - Connect the R wire to the RH terminal.

This connects the heat power.

STEP 2 - Connect the W wire to the W terminal.

This connects the heat.

STEP 3 - Optional - Connect the C wire to the C terminal.

Your heater is now connected to the CT100.

Please Go To Page 6

W

IR

ES

3 Wire Heat

STEP 1 - Connect the R wire to the RH terminal. This connects the heat power.

STEP 2 - Connect the W wire to the W terminal. This connects the heat.

STEP 3 - Connect the G wire to the G terminal on the thermostat. This

connects the fan.

STEP 4 - Optional - Connect the C wire to the C terminal.

Your system is now connected to the CT100.

Please Go To Page 6

C B O W W

2

Y Y

2

R

H

RC G A

POWER

HVAC SYSTEM

THERMOSTAT

W

R

C

THERMOSTAT TERMINALS

HVAC SYSTEM

THERMOSTAT

C B O W W

2

Y Y

2

R

H

RC G A

POWER

W

R

G

C

THERMOSTAT TERMINALS