Lull 1044C-54 Series II Service Manual User Manual

Page 107

Advertising
background image

Supply, Pressure, and Return Hydraulics

31200079

5-25

Removal

Return Filter Assembly

Fig. 5-16: Return Filter Assembly

(Ref. Fig. 5-16) The following procedure describes disassembly of the
return filter assembly.

1. Follow preparation procedures as outlined in Section 3 of this manual.

Be sure to follow the guidelines in this section detailed under “General
Hydraulic Maintenance Practices” on page 5-3.

2. Clean the area around the return filter housing (Item 6).

3. Loosen and remove the return manifold tube (Item 4) connected to the

connector (Item 5) on the hydraulic oil return filter assembly (Item 6).

4. Loosen and remove four (4) capscrews (Item 3) and lockwashers

(Item 2) that secure the hydraulic oil return filter assembly (Item 6) to
the hydraulic oil reservoir (Item 1). Remove the hydraulic oil return filter
assembly. To avoid contamination, place all parts on a clean surface.

5. Remove the rubber gasket (Item 8) and clean it with an appropriate

solvent. Inspect condition of the gasket and replace it if necessary.

K

1097

#

Description

1

Hydraulic Oil Reservoir

2

Lockwasher

3

Capscrew

4

Return Manifold Tube

#

Description

5

Connector

6

Return Hydraulic Oil Filter

7

Diffuser

8

Rubber Gasket

1

2

3

6

5

4

8

7