Boom and Transfer

31200079

6-39

Adding or removing shims from bolted pads may require a different
capscrew length or washer selection.

Fig. 6-28: Determining Capscrew Length

(Ref. Fig. 6-28) Select a combination of capscrew length, flatwasher (if
needed), and lockwasher (spring and/or star) to obtain the required
dimension (Dimension A). This dimension will ensure that the capscrew
will not protrude past the nut insert and cause boom damage. See
Fig. 6-29. Capscrews that can be purchased from JLG come in three (3)
lengths (3/4", 1", and 1-1/4").

Clearance is measured from under the capscrew head to the

lockwasher.

A lockwasher must always be used under the capscrew head.

Apply nonpermanent thread locking compound to the first few threads of
the capscrew before final installation.

Fig. 6-29: Correctly Installed Capscrew

(Ref. Fig. 6-29) The end of the installed capscrew should be flush with, or
just beneath, the inner edge of the nut insert.

Dimension A

Bolted Pad

Nut Insert

Washer

Capscrew

Boom

Lockwasher

J1034

Pad Number

Dimension A

39023A
39024A
39530A
39594A
39604A

0.28"–0.33"
0.39"–0.44"
0.39"–0.44"
0.39"–0.44"
0.21"–0.26"