Section 7 — Frame Tilt and Oscillation

Frame Tilt System

General Description

Fig. 7-1: Frame Tilt System Components

(Ref. Fig. 7-1) The frame tilt system allows the machine to be levelled
laterally (side-to-side) up to 10°, left or right. The lateral angle of the
machine, relative to level ground, is shown on the frame level indicator.

When hydraulic pressure is applied to the frame tilt cylinder the frame
pivots around each axle. Two counterbalance valves (one on the rod end
and one on the base end) are used to inhibit hydraulic fluid from exiting the
frame tilt cylinder.

Function is controlled by the frame tilt control valve (see page 7-3) located
in the operator’s compartment.

Circuit Description

Reference Fig. 7-1 above and Section 4-1, “Reference Diagrams”.

Frame Tilt

Cylinder

Multi-Spool

Frame Tilt

Control Valve

Control Valve

G

1020