Lull 1044C-54 Series II Service Manual User Manual

Page 314

Advertising
background image

Frame Tilt and Oscillation

7-32

31200079

Removal

Oscillation Control Block

Fig. 7-20: Oscillation Control Block Installation

Rear Oscillation Lock Cylinder Installed on Machine

(Ref. Fig. 7-20) Use the following control block removal procedures when
the rear oscillation lock cylinder is installed on the machine. For removal
procedures when the cylinder has been removed, see page 7-33.

1. Follow preparation procedures as outlined in Section 3.

2. Place blocks between frame and top of rear axle. This will hold the

frame in place when the control block is removed.

3. Install brake pressure diagnostic port test gauge onto brake diagnostic

port.

4. While watching test gauge, press brake pedal numerous times until

pressure gauge reads 0 psi. Remove test gauge from diagnostic port.

MV0470

1

9

4

3

5

8

26

29

1

1

6

7

10

1

2

#

Description

1

#6 Hydraulic Hose

2

#8 Hydraulic Hose

3

Capscrew

4

Lockwasher

5

Check Valve Cartridge

#

Description

6

Oscillation Control Block

7

O-Ring

8

Rear Oscillation Lock Cylinder

9

Electrical Lead

10 Pressure Reducing Valve

Advertising