To install National Pipe Thread (NPT) fittings:

1. Apply sealant sparingly to male pipe threads only, avoiding the first few

threads at the end of the fitting.

Note:

Do not use Teflon tape or excessive amounts of sealant. System
contamination will result.

2. Install fitting and tighten per Table 3-8.

Table 3-8: Pipe Thread Fittings (Steel)

Jump Starting Procedures

CAUTION:

• Improper jump starting procedures can cause an explosion resulting in

personal injury.

• Sparks near batteries can cause explosions.

• Do not allow jump cable ends to touch each other or the machine.

• Battery acid can cause personal injury if it contacts skin or eyes.

Always wear eye protection when jump starting a machine.

• Always connect battery positive (+) to battery positive (+) and battery

negative (-) to ground on the machine. Make the final ground connec-
tion away from the battery.

• Allowing the two machines to touch during jump starting can cause

damage to bearings and electrical circuits.

• This machine has a 12 volt starting system. Use the same voltage (12

volts) for jump starting. Use of higher voltage can damage the electri-
cal system.

• Never charge a frozen battery.

Fitting

Size

Thread Size

(NPT)

Turns

1

1.Turns past finger tight

-2

1/8-27

2–3

-4

1/8-27

2–3

-6

1/4-18

1.5–3

-8

3/8-18

2–3

-10

1/2-14

2–3

-12

3/4-14

2–3

-16

1-11.5

1.5–2.5

-20

1 1/4-11.5

1.5–2.5

-24

1 1/2-11.5

1.5–2.5