GENERAL:
1. All service work should be performed in a clean area.
2. Care should be taken to avoid scratching any sealing surfaces or allowing metal chips to come in contact

with the driven magnet assembly.

3. An even, light coat of high vacuum silicon compound (Dow Corning or equivalent) should be applied to all

seals or O’Rings.

4. O’Rings with chamfers should always be installed with chamfer up, away from the groove.
5. All assembly screws should be tightened evenly and in an alternating pattern.
6. Only Micropump factory authorized replacement parts should be used when servicing any Micropump

products.

SPECIFIC:
1. Remove old Bushings (8) with Extraction Tool. The use of a #8 or M4 tap with T-Handle is recommended

(See Figure 1.)

2. New Bushing installation is a press fit. Install using P/N 5465 Tool. (See Figure 2.)