Bryant GAPAAXBB1625 User Manual

Bryant Air purifiers

Advertising
background image

1

Installation, Start--Up, and

Operating Instructions

GAPA

PERFECT AIRT PURIFIER

SIZES 1625 AND 2025

NOTE: Read the entire instruction manual before starting the
install.

This symbol →indicates a change since the last issue.

TABLE OF CONTENTS

Page

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

HOW IT WORKS

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . .

APPLICATION CONSIDERATIONS

2

. . . . . . . . . . . . . . . . . .

INSTALLATION

3--5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP AND OPERATION

6

. . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TROUBLESHOOTING

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SPECIFICATIONS AND DIMENSIONS

8

. . . . . . . . . . . . . . . .

WARRANTY

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

Congratulations for selecting the Perfect Airt Purifier for your

home comfort system! The Perfect Airt Purifier is proven to

remove and kill airborne germs and allergens, including viruses,

bacteria, and mold spores. The Perfect Airt Purifier is a

cornerstone of Bryant’s Perfect AirtSolutions for providing

healthier, cleaner air in your home.

HOW IT WORKS

The Perfect Airt Purifier provides extremely high filtration

performance while killing captured contaminants, including

viruses, bacteria, and mold spores. The Perfect Airt Purifier

treats the entire air--stream through a state of the art, three--stage

process, exclusive to Bryant.
In stage one, the particles are electrically charged by a

precision--point ionization array as they enter the Perfect Airt

Purifier.
In stage two, the charged particles are electrically attracted to

the air purification cartridge, which is located within an electric

field.
In stage three, captured particles are killed by electrical current

flow and ion bombardment.

A06054

Fig. 1 -- GAPA Unit

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service,

maintenance, or use can cause explosion, fire, electrical shock

or other conditions which may cause personal injury or property

damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The

qualified installer or agency must use factory authorized kits or

accessories when modifying this product. Refer to the

individual instructions packaged with the kits or accessories

when installing.
Follow all safety codes. Wear safety glasses and work gloves.

Have fire extinguisher available. Read these instructions

thoroughly and follow all warning or cautions attached to the

unit. Consult local building codes and National Electrical Code

(NEC) for special requirements.
It is important to recognize safety information. This is the
safety--alert symbol

. When you see this symbol on the unit

and in instructions or manuals, be alert to the potential for

personal injury. Understand the signal words DANGER,

WARNING, and CAUTION. These words are used with the

safety--alert symbol. DANGER identifies the most serious

hazards which will result in severe personal injury or death.

WARNING signifies hazards which could result in personal

injury or death. CAUTION is used to identify unsafe practices

which may result in personal injury or product and property

damage. NOTE is used to highlight suggestions which will

result in enhanced installation, reliability, or operation.