7. Daily Inspection and Maintenance

At the start of each work day (or 8 hour shift), an
MHP13/35 qual i fied op er a tor must per form the
Daily In spec tion and Main te nance as listed in the
ta ble be low.

The pur pose of the Daily In spec tion and Main te -
nance is to keep the MHP13/35 in proper work ing
con di tion and to de tect signs of mal func tion at the
ear li est pos si ble time.

The MHP13/35 should be in the STOWED
POSITION and the Mas ter Key Switch set to OFF
be fore you be gin this in spec tion.

De fec tive parts and/or equip ment mal func tions
jeop ar dize the safety of the op er a tor and other per -
son nel, and can cause dam age to the ma chine.

The potential for an accident increases when
operating an MHP that is damaged or
malfunctioning. Death or serious injury can
result from such accidents. Do not operate
an MHP that is damaged or malfunctioning.

MHP13/35 – 12431A

page 7 - 1

Item

Service Required

Engine fuel level

Look to see that the fuel tank is full

Fuel tank cap

Check to see that the cap is tight

Engine oil level

Check oil level (between dipstick lines)

Fuel leaks

Visually inspect (hoses and connections)

Operator's manual

Check that it is in the holder on the machine

Wiring harnesses

Visually inspect (installation, condition)

Battery terminals

Visually inspect (no corrosion)

Battery fluid level

Check fluid level (1/4" or 6 mm below filler neck)

Hydraulic oil level

Visually inspect level (between lines on gauge)

Hydraulic oil leaks

Visually inspect (hoses, tubes)

Tires and wheels

Visually inspect (condition)

Bolts and fasteners

Visually inspect (condition)

Structural damage and welds

Visually inspect (weld cracks, dents)

Lanyard anchor points

Visually inspect (condition)

Platform gravity gate

Check condition and operation

Platform guardrails

Visually inspect (condition)

Flashing light (option)

Visually inspect (operation)

Ground control switches

Actuate and inspect for proper operation

Level sensor (option)

Check operation

Emergency lower

Check operation (causes correct motion)

Platform control box switches

Actuate and inspect for proper operation

RCD/ELCB AC outlet (option)

Check operation

Platform work lights (option)

Check operation

Placards and decals

Visually inspect (installation, condition)