Upper control station 8-8, Guardrail system 8-8, Platform extension 8-8 – Snorkel S2545 User Manual

Page 32: Swing-down rails 8-8, Operating controls 8-8, Guardrail system, 8-8, Mid rail, 8-8, Safety chain, 8-8, Swinging gate, 8-8, Toeboards, 8-8

Advertising
background image

Upper Control Station

Inspect the platform and upper controls only if all
functions operated properly from the lower
controls.

Guardrail System

The guardrail system (refer to Figure 8.20)
includes the top rail, mid rail, toeboards and a
safety chain or optional swinging gate.

Figure 8.20—Guardrail System

Inspect all components of the guardrail system.
The rails and toeboards must all be in place and
free of any damage or deformation. Visually
check the rail and toeboard welds for cracks. All
bolts and nuts fastening the guardrails in place
must be present and not show any signs of
looseness.

Inspect the lift up gate at the platform entrance to
be sure it is present and securely fastened to the
rail. The gate must be free of damage and
deformation that may prevent if from functioning
properly. Inspect the detent pins that secure the
gate.

Inspect the safety chain to be sure it is present
and securely fastened to the rail. The chain must
be free of damage and deformation that may
prevent if from functioning properly. Inspect the
hook and eye that secures the chain to the rail.

Inspect the swinging gate to see that it swings
freely, closes firmly, and is not deformed in any
way. Make sure the latch closes and secures the
gate when the gate is closed.

Platform Extension

Inspect the extension latch (refer to Figure 8.21)
to ensure that it properly secures the extended
platform. The latch must also release to extend
the platform. Extend the platform while checking
for proper operation.

Figure 8.21—Platform Extension Latch

Extend the platform and inspect the weldments
for deformation and damage. Visually check the
platform welds for cracks.

Swing-Down Rails

Inspect the snapper and detent pins to make sure
they are in place and are not deformed. There
are two snapper pins and two detent pins at the
front and rear of the platform. The pins must
securely fasten the swing-down rails in the
upright position.

Operating Controls

With the aerial platform stowed, test the
operation of each control from the upper control
station (refer to Figure 8.22).

Figure 8.22—Upper Controls

From the lower controls, place the battery
disconnect switch in the on position and the
control selector in the up position. Lift the red
emergency stop safety guard up and push the
toggle switch up to turn on the electrical power to
the upper controls.

page 8 - 8

S2545 – 0410002

Chapter 8. Prestart Inspection

Top Rail

Mid Rail

Toeboard

Entry Chain

Latch

Horn
Button

Steer
Switch

Interlock
Switch

Drive/Lift
Selector
Switch

Joystick

Emergency Stop Button

Battery
Condition
Indicator

Low Voltage
Warning Light

Advertising