0

Physical range check high for exhaust gas back pressure burner; shut
off regeneration

768

523920

1

Physical range check low for exhaust gas back pressure burner; shut
off regeneration

770

523920

3

Sensor error exhaust gas back pressure burner; signal range check high

771

523920

4

Sensor error exhaust gas back pressure burner; signal range check low

776

102

3

Sensor error charged air pressure; signal range check high

777

102

4

Sensor error charged air pressure; signal range check low

791

411

0

Physical range check high for differential pressure Venturi unit (EGR)

792

411

1

Physical range check low for differential pressure Venturi unit (EGR)

793

411

11

Sensor differential pressure Venturi unit (EGR); plausibility error

794

411

2

Sensor differential pressure Venturi unit (EGR); CAN signal invalid

795

411

3

Sensor error differential pressure Venturi unit (EGR); signal range check high

796

411

4

Sensor error differential pressure Venturi unit (EGR); signal range check low

805

524025

14

Particulate filter; regeneration not successful

807

3253

2

Sensor differential pressure (DPF); plausibility error regarding signal offset

809

3251

0

Physical range check high for differential pressure (DPF); shut
off regeneration

812

3251

1

Physical range check low for differential pressure (DPF); shut
off regeneration

814

3253

3

Sensor error differential pressure (DPF); signal range check high

815

3253

4

Sensor error differential pressure (DPF); signal range check low

825

523009

9

Pressure Relief Valve (PRV) reached maximum allowed opening count

826

523470

2

Pressure Relief Valve (PRV) forced to open; performed by pressure increase

827

523470

2

Pressure Relief Valve (PRV) forced to open; performed by pressure shock

828

523470

12

Open Pressure Relief Valve (PRV); shut off condition

829

523470

12

Open Pressure Relief Valve (PRV); warning condition

830

523470

14

Pressure Relief Valve (PRV) is open

831

523470

11

The PRV can not be opened at this operating point with a pressure shock

832

523470

11

Rail pressure out of tolerance range

833

523009

10

Pressure relief valve (PRV) reached maximum allowed open time

834

523906

5

Electrical fuel pre - supply pump; open load

835

523906

12

Electrical fuel pre - supply pump; power stage over temperature

836

523906

3

Electrical fuel pre - supply pump; short circuit to battery

837

523906

4

Electrical fuel pre - supply pump; short circuit to ground

838

523450

3

Multiple Stage Switch constant speed; short circuit to battery

839

523450

4

Multiple Stage Switch constant speed; short circuit to ground

840

523450

2

Multiple Stage Switch constant speed; plausibility error

841

523451

3

Multiple Stage Switch engine speed control parameter; short circuit
to battery

842

523451

4

Multiple Stage Switch engine speed control parameter; short circuit
to ground

843

523451

2

Multiple Stage Switch engine speed control parameter; plausibility error

844

523452

3

Multiple Stage Switch engine torque limitation curve; short circuit to battery

845

523452

4

Multiple Stage Switch engine torque limitation curve; short circuit to ground

Fault

Codes

SPN

Codes

FMI

Codes

Deutz Description

Advertising
This manual is related to the following products: