Calibration values -7 – JLG LSS Scissors User Manual

Page 19

Advertising
background image

SECTION 2 - OPERATION - (LE, MRT, RTS)

3124288

– JLG Lift –

2-7

Pressing the ENTER key will confirm that the platform is
empty (except for factory-installed options outside the
Rated Load). The LSS Module will calculate the total of all
load cell readings and ensure that the total is greater than
minimum calibration value, but less than maximum cali-
bration value. If successful, the Analyzer will show the fol-
lowing:

CALIBRATE:
COMPLETE

If the empty platform weight is less than minimum calibra-
tion value, the calibration attempt will be unsuccessful and
the Analyzer will show the following:

CALIBRATE:
< MIN CAL

If the empty platform weight is greater than maximum cali-
bration value, the calibration attempt will be unsuccessful
and the Analyzer will show the following:

CALIBRATE:
> MAX CAL

Table 2-5. Calibration Values

MODELS

4069LE

3969LE

500RTS

260MRT

Minimum Cali-

bration Value

850 lb

(385 kg)

850 lb

(385 kg)

1100 lb

(499 kg)

750 lb

(340 kg)

Maximum Cali-

bration Value

1425 lb

(646 kg)

1425 lb

(646 kg)

2950 lb

(1338 kg)

1250 lb

(567 kg)

Advertising