SECTION 4 - OPERATION - (RS)

3124288

– JLG Lift –

4-7

Table 4-5. Load Calibration Failure Troubleshooting (RS Only)

LOAD CALIBRATION FAILURE

(Displayed on Analyzer 2nd Line)

DESCRIPTION

CHECK

NOT IN GND MODE

The machine is not in Ground Mode.

• Set the key switch so that the machine is in

Ground Mode.

• The machine must be in ground Mode for

Load calibration.

CAL ANGLE

The Angle Sensor has not been calibrated.

• Navigate to the Calibrations menu and

enter the Angle submenu to perform Angle
Sensor calibration.

• The Angle sensor must be calibrated

before Load calibration can occur.

PLAT NOT STOWED

The machines platform is not stowed.

• Ensure that the platform is stowed and per-

form the Load calibration again.

MOTION STOPPED

The platform stopped moving during calibra-
tion.

• The technician let go of the lift up switch

before the machine reached maximum ele-
vation during "CAL LOAD: LIFT TO MAX
ELEV".

CAL FAIL

The technician has pressed ESC on the Ana-
lyzer during the calibration routine.