All300 troubleshooting guide, Cont – Aladdin Light Lift ALL300-CM User Manual

Page 13

Advertising
background image

ALL300 TROUBLESHOOTING GUIDE

cont.

1. Confirm ALL300 is at the CEILING POSITION. If not, use the controller to operate the ALL300 to

the CEILING POSITION. Chandelier will only light at the CEILING POSITION. If operated to the

CEILING POSITION and the chandelier will still not light, proceed to step 2.

2. Confirm light switch in the square box is turned on. The square box is mounted on the chassis plate of

the ALL300, right in front of the control board. If it was found in the off position, flip it to the on position

and to test the chandelier. If chandelier still does not light, proceed to step 3.

3. Turn the motor and light switch in the square box to the off position. Confirm light fuse is good. The

light fuse is held to the control board by fuse clips and is located right in front of the light relay. Remove

and perform a continuity test on the light fuse. If the fuse reads continuity, place it back in the fuse clips.

If it does not read continuity, it must be replaced with a new, 15 amp, fast blow fuse. If the ALL300 was

equipped with a 2200 watt upgrade package, replace with a new, 20 amp, fast blow fuse. Turn the motor

and light switch in the square box to the on position, and test the chandelier. If the chandelier still does not

light, proceed to step 4.

4. From where the ALL300 is installed, call Aladdin Light Lift technical support Monday through Friday

during normal business hours at (877) 287-4601. A voltage meter will be needed to further test the

ALL300.

SYMPTOM: ALL300 WILL NOT SHUT OFF PROPERLY AT CEILING POSITION:

Discontinue use immediately and contact Aladdin Light Lift at (877) 287-4601.

After all troubleshooting is complete, replace control board cover.

WHITE

OR

PURPLE

GREEN OR ORANGE

RED OR BROWN

Replace with same type (ABC)

same amp, fast acting fuse:

ALL200-15A,250V ALL700-20A,250V

ALL300-15A,250V ALL1000-20A,250V

W

hite or Pu

rp

le (C

OMMON)

Green or Orange (NO)

Red or Brown (NC)

Replace with same type (GDC)

same amp, slow blow fuse:

ALL200-1.6A,250V ALL700-1.6A,250V

ALL300-1A,250V ALL1000-1.6A,250V

NOTE:

When installing a new circuit board, please see the

key below for the wiring of the limit switch wire to

the new circuit board:

COM = WHITE OR PURPLE WIRE

NO = GREEN OR ORANGE WIRE

NC = RED OR BROWN WIRE

Limit switches must be wired as seen in diagram below. If not wired correctly, this could

cause the chandelier to fall, which could cause death, personal injury, and/or property

damage.