Bakers Pride XMG-24,-36,-48,-60,-72 Manual User Manual

Page 2

Advertising
background image

2

1. Installation Instructions

2

A

Safety Precautions

2

B Unpacking Instructions

3

C Gas Connections

3

D Electric Installation (XSG model only)

3

E Leveling Adjustment

4

2. Lighting Instructions

4

XSG, XTG, XMG

-24

60,000

60,000

XSG, XTG, XMG

-36

90,000

90,000

XSG, XTG, XMG

-48

120,000

120,000

XSG, XTG, XMG

-60

150,000

150,000

XSG, XTG, XMG

-72

180,000

180,000

GAS SPECIFICATIONS

Propane Gas Natural Gas
BTU/HR @ 10” W.C. BTU/HR @ 3.5” W.C.

Model Number

XSG units are equipped with snap action thermostats and standing pilot systems. This griddle must have
115V, 60 Hz electrical power to operate the main burners. This appliance will not operate during a power
failure. No attempt should be made to operate this gas appliance during power failure.

XTG units are equipped with throttle type thermostat and standing pilot (no pilot safety provided)

XMG units are equipped with manual gas valves, and standing pilot (no pilot safety provided). No griddle
plate temperature control is provided.

CONTENTS

A

Lighting Instructions

4

B Shutdown Instructions

4

3. Cleaning Instructions

5

4. Maintenance Instructions

5

5. Wiring Diagram (XSG Only)

6

6. Parts List & Exploded View

7

7. Warranty

11

1. INSTALLATION INSTRUCTIONS

A.

SAFETY PRECAUTIONS

FOR YOUR SAFETY, THE FOLLOWING SAFETY PRECAUTIONS SHOULD BE FOLLOWED AND
ENFORCED.

IF YOU SMELL GAS:

SHUT OFF GAS SUPPLY TO APPLIANCE
EXTINGUISH OPEN FLAMES
IMMEDIATELY CALL YOUR GAS SUPPLIER

1.

A separate gas shut-off valve should be installed in the gas line ahead of the unit, as required by
codes.

2.

LIGHTING: Follow the instructions on page 5.

3.

At least 24 inches must be provided at the front of unit for servicing.

4.

When installing, never enclose the bottom area of the unit with a raised curb or other construction
that would obstruct the flow of air into the unit.

5.

This unit may be operated with 0” (side and back) minimum clearance to non-combustible
construction materials.

6.

This installation must conform to local codes, or in absence of local codes to the National Fuel Gas
Code ANSI Z223.1, latest edition. In Canada it must conform to current National Standard
CAN/CGA B 149.1 (natural gas) or CAN/CGA B 149.2 (propane) Installation Code for Gas Burning
Appliances & Equipment.

7.

!
!
!

In MASSACHUSETTS: All gas products must be installed by a “Massachusetts” licensed plumber
or gas fitter. Ventilation hoods must be installed in accordance with NFPA-96, current edition, with
interlocks as described in that standard.