Bakers Pride XMG-24,-36,-48,-60,-72 Manual User Manual

Page 3

Advertising
background image

Figure “A”

Main Shut-Off Valve

Pressure Regulator

Flue

clean and free of dirt, piping compound and
obstruction. To insure maximum operating
efficiency, this appliance must be connected with a
Gas Supply Line of solid pipe or with a Commercial
Type Flexible Connector with I.D. (inside diameter)
equal or larger than the gas pipe inlet on this
appliance.

CAUTION: BEFORE LIGHTING, CHECK ALL
JOINTS IN THE GAS SUPPLY LINE FOR LEAKS.
USE SOAP AND WATER SOLUTION. DO NOT
USE OPEN FLAME.

If the gas connections are leak-free, the unit is ready
to use. Follow the lighting instructions.

D. ELECTRIC INSTALLATION (XSG ONLY)

This appliance when installed must be electrically grounded in accordance with local codes, or in
the absence of local codes, with the National Electrical Code, ANSI/NFPA 70,
or the Canadian
Electrical Code, CSA C22.2,
as applicable.

The installation of electric wiring from the electric meter, the main control box, and the outlet to the electric
appliance must be electrically grounded in accordance with local codes, or in the absence of local codes
with the National Electric Code ANSI/NFPA 70. In Canada, follow the Canadian Electric Code CSA-C 22.2.
All work should be done by qualified installation personnel.

Electrical diagram (model XSG only) is located on the right side of the unit.

WARNING-ELECTRICAL GROUNDING INSTRUCTION

This appliance is equipped with a three-prong (grounding) plug for your protection against shock

8.

Electrical diagram (model XSG only) is located on the right side of the unit.

9.

The appliance and its individual shut-off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2” psi (3.45 kPa).

10.

The appliance must be isolated from the gas supply piping system by closing its individual manual
shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to
or less than ½” psi (3.45kPa).

11.

This appliance must be installed under a ventilation hood.

12.

Do not obstruct the flow of combustion and ventilation air.

13.

The area around this or any other gas appliance must always be kept free and clear from
combustibles.

RETAIN THIS MANUAL FOR FUTURE REFERENCE.

B. UNPACKING INSTRUCTIONS:

Carefully unpack the griddle and inspect immediately for shipping damages. Your Griddle was shipped in a
carton designed to give maximum protection in normal handling. It was thoroughly inspected before leaving
the factory and the carrier accepted and signed for it. File any claims for shipping damage or irregularities
with the carrier.

A separate gas shut off valve (supplied with unit) must be installed in the gas line ahead of the unit, as
required by codes (see Fig. A).. Gas supply line must be ¾” or larger. If flexible semi rigid connections are
used, the inside diameter must be the equivalent of ¾” iron pipe or larger. All connections of the flexible and
semi rigid type must be AGA listed and comply with applicable ANSI standards. Make sure gas piping is

C. GAS CONNECTIONS

3

Advertising
This manual is related to the following products: