TROUBLESHOOTING CHART

Burners & pilots will

not turn on

Burners produce

excessive carbon

deposits

Pilot will not remain

lit.

Griddle doesn't

seem hot enough

Griddle surface too

hot

Burners won't turn

on (XSG only)

Main gas supply to range is not

turned on.

Incorrect gas type.

Incorrect gas supply pressure.

Incorrect orifices.

Primary air not adjusted properly.

Pilot flame adjusted incorrectly.

Draft condition.

Orifices may be dirty/clogged.

Low gas pressure.

Thermostat set too high.

Thermostat defective.

Unit unplugged.

No power to outlet.

Turn on main gas supply.

Supply correct type gas.

Call local gas supplier.

Call Bakers Pride authorized service

center.

Adjust air shutter.

Adjust pilot flame.

Remove draft.

When unit cools, check & clean orifices.

Increase gas pressure to 3.5" W.C. (Nat)

or 10" W.C. (L.P.)

Reduce thermostat setting.

Replace thermostat.

Plug unit in.

Replace fuse or reset circuit breaker.

PROBLEM PROBABLE CAUSE SOLUTION

6

1.

Burner ports must be thoroughly cleaned. Venturi must be free from grease and lint.

2.

All places where oil, grease or food can accumulate must be kept clean all the time.

3.

Pilot light must be kept clean and adjusted at the proper flame height to assure constant ignition and
to prevent fire flash-outs caused by delayed ignition.

4.

Appliance flue has to be kept clean and free of any obstruction to ensure unrestricted flow of
combustion products from the unit.

5.

Carelessness, abusive handling, or altering equipment can shorten the life of the equipment and
jeopardize the limited warranty offered by Baker's Pride.

If you have any questions concerning the installation, operation, maintenance or service of this
product please contact Bakers Pride’s Technical Service Department at (800) 431-2745 US &
Canada.

Figure “C”

5. WIRING DIAGRAM - MODEL XSG ONLY (See Figure C)

120VAC

Black

White

Green

Electrical Box

Control Panel

Solenoid

Valve

Coils

Thermostats

450°F

Power

Switch

Neon

Indicator

Lamps

C1

C2

C3

C4

C5

C6

T6

T5

T4

T3

T2

T1

N1

N2

N3

N4

N5

N6

72”

60”

48”

36”

24”

Advertising
This manual is related to the following products: