Bakers Pride XOB-848SU Manual User Manual

Page 3

Advertising
background image

3

1. INSTALLATION INSTRUCTIONS

SECTION

ITEM

PAGE

A

Safety Precautions

3

B

Unpacking Instructions

4

C

Gas Connection

4


2. LIGHTING INSTRUCTIONS

SECTION

ITEM

PAGE

A

Lighting Instructions

4

B

Shutdown Instructions

4

GAS SPECIFICATIONS

Propane Gas Natural Gas
BTU/HR @ 10” W.C. BTU/HR @ 3.5” W.C.

Model Number

XOB-212, XOB-212SU
XOB-424, XOB-424S
XOB-636, XOB-636SU

XOB-848, XOB-848SU

60,000

60,000

120,000

120,000

180,000

180,000

240,000

240,000

1. INSTALLATION INSTRUCTIONS

A.

SAFETY PRECAUTIONS

FOR YOUR SAFETY, THE FOLLOWING SAFETY PRECAUTIONS SHOULD BE FOLLOWED
AND ENFORCED.

IF YOU SMELL GAS:

SHUT OFF GAS SUPPLY TO APPLIANCE
EXTINGUISH OPEN FLAMES

·

IMMEDIATELY CALL YOUR GAS SUPPLIER

Instructions must be posted in a prominent location. All safety precautions must be taken in the event the
user smells gas. Safety information can be obtained from your local gas supplier.

1. A separate gas shut-off valve must be installed in the gas line ahead of the unit, as required by

codes.

2. LIGHTING: Follow the instructions on page 4.
3. At least 24 inches must be provided at the front of for servicing.
4. When installing, never enclose the bottom area of the unit with a raised curb or other

construction that would obstruct the flow of air into the unit.

5. This unit may be operated with 0” (sides and back) minimum clearance to non-combustible

construction in areas that are non-combustible locations only.

6. This installation must conform to local codes, or in absence of local codes to the National Fuel

Gas Code ANSI Z223.1/NFPA 54, latest edition. In Canada it must conform to current Natural
Gas Installation Code CAN/CGA B 149.1
(natural gas) or CAN/CGA B 149.2 Propane
Installation Code for Gas Burning Appliances & Equipment.

7. The appliance and its individual shut-off valve must be disconnected from the gas supply piping

system during any pressure testing of that system at test pressures in excess of ½ psi (3.45

In MASSACHUSETTS: All gas products must be installed by a “Massachusetts” licensed plumber or
gas fitter. Ventilation hoods must be installed in accordance with NFPA-96, current edition, with
interlocks as described in that standard.

CONTENTS

3. MAINTENANCE INSTRUCTIONS

SECTION

ITEM

PAGE

A

Cleaning Instructions

5

B

Maintenance Instructions

5

C

Troubleshooting Chart

5

D

Parts List & Exploded View

6

4. WARRANTY

8

Advertising