Clarus Environmental Pipe Boot Seal User Manual

Pipe boot seal installation instructions

Advertising
background image

SECTION: C3.20.165

CL0157

0314

Supersedes

New

© Copyright 2014. All rights reserved.

Pipe Boot Seal Installation Instructions

SEE NOTE #1

CUT PIPE BOOT ABOVE

REINFORCING RING

SEE NOTE #8

LAP SEALANT

FIELD OR FACTORY SEAM

6" X 6" LAP JOINT COVER STRIP

INSTRUCTIONS:

1-PIPE BOOTS MUST BE CUT TO SIZE.

2-APPLY QuickPrime Plus TO MEMBRANE WHERE

THE PIPE BOOT WILL BE PLACED.

(SEE QuickPrime Plus DIRECTIONS)

3-REMOVE THE PROTECTIVE PAPER FROM THE

PIPE BOOT.

4-MATE THE PIPE BOOT TO THE MEMBRANE.

(DO NOT TRY TO PULL UP TO TEST SEAL).

5-ROLL THE FLANGE WITH A 2" ROLLER.

6-APPLY LAP SEALANT WHERE THE PIPE MEETS THE

PIPE BOOT.

7-TIGHTEN THE HOSE CLAMP AROUND THE PIPE

BOOT AND PIPE. (ENSURE THERE ARE NO

WRINKLES OR FOLDS UNDER THE HOSE CLAMP).

8-IF THE FLANGE OF THE PIPE BOOT OVERLAPS A

FIELD OR FACTORY SEAM APPLY LAP SEALANT CAULK

AROUND THE EDGE OF THE PIPE BOOT AND THEN

PLACE A 6" X 6" COVER STRIP OVER THE BOOT

AND SEAM.

PondGard/RubberGard MEMBRANE

LAP SEALANT

STAINLESS STEEL

HOSE CLAMP

PIPE BOOT SEAL

SEE NOTE 1

QuickPrime Plus

SEE NOTE 2

SK2483

3649 Cane Run Road Louisville, KY 40211-1961

800-928-7867 Fax: 502-774-3624

www.clarusenvironmental.com

®

®

Advertising