Beckett AQUASMART 7600 User Manual

Control replacement cross-reference guide, Back, Features & benefi ts

Advertising
background image

PARTS & ACCESSORIES

Control Replacement Cross-Reference Guide

Model 7600 Boiler Control

R.W. Beckett Corporation

Mail: P.O. Box 1289, Elyria, OH 44036 ● Phone: 800-OIL-BURN (800-645-2876) ● FAX: (440)327-1064

R.W. Beckett Canada Ltd.

Unit 3 - 430 Laird Road, Guelph, Ontario, Canada N1G 3X7 ● Phone: 800-665-6972 ● FAX: (519)763-5656
www.beckettcorp.com

Table 1 - Direct Replacements

Honeywell

Beckett Replacement

Notes

L8124A (All)

L8124C (All)

7600A

7600 outputs are not rated for 240 VAC.

L7124A (All)
L7124C (All)
L7148A (All)
L7224A (All)

L7224C (All)
L7224U (All)
L7248A (All)
L7248C (All)

7600A

The 7600 has no Honeywell EnviraCOM

TM

Communications port. The diagnostic LED

lights are replaced by the 7600’s display.

L8148A (All)

7600A

7600 outputs are not rated for 240 VAC. B1 terminal on 7600 utilizes a 1/4” quick
connect. Set low limit on 7600 to OFF.

L8124E 1016

L8148E 1265

7600B

7600 outputs are not rated for 240 VAC. B2, TW and TR terminals replace TV, T and Z,
respectively.

L8124M (All)

7600A

For replacement with the 7600: Turn low limit off so the circulator is controlled directly by
the thermostat and ZC is constantly powered.

L8151A

7600A

7600 outputs are not rated for 240 VAC. Remote mount sensor cable needed (Part No.
52120)

Hydrolevel

Beckett Replacement

Notes

3100

7600B

Not a suitable replacement if Low Water Cutoff (LWCO) functionality is used.

3150

7600A

Carlin

Beckett Replacement

Notes

90524A

7600A

Make sure 7600 outputs do not exceed 7.4A. Available operating limit and differential
ranges are not equivalent.

White Rodgers

Beckett Replacement

Notes

11C15-11

7600A

Make sure 7600 outputs do not exceed 7.4A @ 120 VAC. 7600 outputs are not rated for 240 VAC.
Available operating limit and differential ranges may not be equivalent.

11C30-3

11B54-4

8B48A-217

11C61-12

Not a suitable replacement if SPDT switch action is required; only break-on-rise available on 7600.
Make sure 7600 outputs do not exceed 7.4A @ 120 VAC. 7600 outputs are not rated for 240 VAC.

8F48A-351

8B43A-601

7600B

More on

Back

Features & Benefi ts

Beckett HeatManager

TM

dynamic temperature reset

Energy saving through circulator-off delay
Priority override for domestic hot water
Freeze resistance
2N1 self checking sensor w/ Low Water Cut-off
Cycle history diagnostic information
Backlit LCD screen with programming touch pad
Reduce inventory through universal design
Backlit LCD screen with programming touch pad
Built-in power disconnect switch (optional)
Oil and gas offerings available
Cold-Start compatible