IV. C

ONTROL

S

YSTEM

S

PECIFICATIONS

Controller Specifications

• Power requirements

12VDC (9VDC to 14VDC)

• Control current

• Monitor motor run current for left-right

• Monitor motor run current for up-down

0.15 A
4.5 - 5 A* @ 200psi
4.5 - 5 A* @ 200psi

• Monitor motor stall current

27 A

• Current limit trip-out

6 A

• Nozzle motor run current

0.5 A

• Operating temperature range

-40

°F (-40°C) to 176°F (80°C)

Shock:

• 30 G's (55 Hz. @ .2 inch double amplitude)

Vibration:

15.5 G's (55 Hz. @ .05 inch double amplitude) continuous operation

Environmental:

• All enclosures have a NEMA 4 rating (must withstand a 1 inch stream of water (65GPM)

from a distance of ten feet for five minutes, with no water entering the enclosure).