B. electrical connections, System wiring diagrams, Electrical connections – Elkhart Brass Scorpion 8394-04 User Manual

Page 15: Left-stow) relay control module, Relay control module

Advertising
background image

12


B. Electrical Connections

1. System Wiring Diagrams

Refer to the appropriate wiring diagram (Found in instruction packet 98421001 included with
81480001 or 81480011Relay Control Module)

¾

Drawing Number 30189000 (Part Number 98284010) With Stow and OEM supplied

primary controls

¾

Drawing Number 30194000 (Part Number 98284020) No Stow with Elkhart Brass

supplied primary controls

¾

Drawing Number 30205000 (Part Number 98284030) With Stow and Elkhart Brass

supplied primary controls

2. Monitor to (81480001 Center-Stow or 81480011 Left-Stow) Relay Control
Module

¾

Route cable with 6-conductor molded connector from 81480001 relay box to

corresponding connector on monitor harness near inlet flange. Plug connector halves
together.

¾

Use cushioned clamps to secure cable to appropriate structural members, being sure

to locate cable in protected areas.

3. 81339001 Primary Control Switch Module to (81480001 Center-Stow or
81480011 Left-Stow) Relay Control Module

¾

Route remaining unused cable from 81480001 relay box to weather proof junction

box (installer supplied). Insert cable through weather proof strain relief into box, and
tighten strain relief nut.

¾

If junction box is within four feet cable length of 81339001 control switch module,

use Elkhart #36802000 harness assembly. (If cable distance from control switch
module to junction box exceeds four feet, use 36804000 extension harness (10ft.).)
Join Packard Metri-Pak connector on harness to mating connector on switch control
module, and route harness to junction box. Insert harness through weather proof
strain relief fitting into junction box. Strip off suitable length of outer jacket from
both cables in junction box, then strip each individual conductor. Make secure,
insulated splices of matching color wires. Install junction box lid.

¾

If dual switch modules are required (i.e. one control on each pump panel), see wiring

diagram for required wye harness and extension harness.

4. 81340001 Secondary Switch Box to (81480001 Center-Stow or 81480011 Left-
Stow) Relay Control Module

¾

Route 9-conductor cable (with warning tag) from relay box to switch box, and secure

cable with cushioned clamps.

¾

Remove lid from switch box by loosening the four screws at corners, loosen nut on

cable strain relief fitting, and insert cable through fitting approximately 6 inches.