Single supply, Separate auxiliary supply – ElmoMC SimplIQ Digital Servo Drives-Whistle Installation Guide User Manual

Page 28

Advertising
background image

Whistle and Tweeter Installation Guide

Installation

MAN-WHTWIG (Ver. 1.604)

www.elmomc.com

28

3.8.1.

Single Supply

A single isolated DC power supply can provide power for both the main power and the Auxiliary
(Drive Logic) Supply in up to 100 V models. The drawing below shows how a single supply is
connected.

Figure 8: Single Supply for both the Main Power Supply and

the Auxiliary Supply in Up to 100 V Models

Note:

For 200 V models, it is forbidden to connect VL to VP+. Two separate power supplies are

required

3.8.2.

Separate Auxiliary Supply

Power to the Auxiliary Supply can be provided by a separate Auxiliary Supply.

Figure 9: Separate Auxiliary Supply Connection Diagram

Advertising