Built-in protection, Accessories, Status indication – ElmoMC SimplIQ Digital Servo Drives-Whistle Installation Guide User Manual

Page 55: Automatic procedures

Advertising
background image

Whistle and Tweeter Installation Guide

Technical Specifications

MAN-WHTWIG (Ver. 1.604)

www.elmomc.com

55

4.1.7.

Built-In Protection

Software error handling

Abort (hard stops and soft stops)

Status reporting

Protection against:

Shorts between motor power outputs

Shorts between motor power output and power input/return

Failure of internal power supplies

Over temperature

Cont. temperature measurement. Temp can be read on the fly, Warning can be

initiated X degrees before temp disable is activated.

Over/Under voltage

Loss of feedback

Following error

Current limits

4.1.8.

Accessories

External heatsink (Whistle). See Section 3.4.1 for more details. Catalog number:

WHI-HEATSINK-2.

Evaluation Board. See Section 3.16 for a picture and more details. Catalog number:

EVA-WHI/GUI/BEL.

Cable Kit. See Section 3.16 for more details. Catalog number: CBL-EVAUNIKIT01.

4.1.9.

Status Indication

Output for a bi-color LED

4.1.10. Automatic Procedures

Commutation alignment

Phase sequencing

Current loop offset adjustment

Current loop gain tuning

Current gain scheduling

Velocity loop offset adjustment

Velocity gain tuning

Velocity gain scheduling

Position gain tuning