Tweeter, Auxiliary supply, Tweeter 4.3.3. auxiliary supply – ElmoMC SimplIQ Digital Servo Drives-Whistle Installation Guide User Manual

Page 59

Advertising
background image

Whistle and Tweeter Installation Guide

Technical Specifications

MAN-WHTWIG (Ver. 1.604)

www.elmomc.com

59

4.3.2.

Tweeter

Feature

Units

3/60

2.5/100

Minimum supply voltage

VDC

7.5

12

Nominal supply voltage

VDC

50

85

Maximum supply voltage

VDC

59

95

Maximum continuous

power output

W

160

200

Efficiency at rated power (at

nominal conditions)

%

> 99

Maximum output voltage

> 95% of DC bus voltage at f=22 kHz

Auxiliary power supply

VDC

12 to 95 VDC (up to 2.5 VA inc. 5 V/200 mA for encoder)

Amplitude sinusoidal/

DC continuous current

A

3.3

2.5

Sinusoidal continuous RMS

current limit (Ic)

A

2.3

1.8

Peak current limit

A

2 x Ic

Weight

g (oz)

27 g (0.95 oz)

Dimensions

mm (in)

51 x 12.5 x 42 (2" x 0.49" x 1.65")

Digital in/Digital out/Analog in

6/2/1

Mounting method

PCB mount or soldered pins

4.3.3.

Auxiliary Supply

Feature

Details

Auxiliary power supply

Isolated DC source only

Auxiliary supply input voltage

12 VDC to 95 VDC

Auxiliary supply input power

< 2.5 VA (this includes the 5 V/200 mA load for
the main encoder only)

Advertising