Environmental conditions, Control specifications, Current loop – ElmoMC SimplIQ Digital Servo Drives-Whistle Installation Guide User Manual

Page 60: Control specifications 4.4.2. current loop

Advertising
background image

Whistle and Tweeter Installation Guide

Technical Specifications

MAN-WHTWIG (Ver. 1.604)

www.elmomc.com

60

4.4. Environmental Conditions

Feature

Details

Operating ambient temperature

according to IEC60068-2-2

0 °C to 40 °C (32 °F to 104 °F)

Storage temperature

-20 °C to +85 °C ( -4 °F to +185 °F)

Maximum non-condensing

humidity

according to IEC60068-2-78

95%

Maximum Operating Altitude

2,000 m (6562 feet)

Mechanical Shock

according to IEC60068-2-27

15g / 11ms Half Sine

Vibration

according to IEC60068-2-6

5 Hz ≤ f ≤ 10 Hz: ±10mm
10 Hz ≤ f ≤ 57 Hz: 4G
57 Hz ≤ f ≤ 500 Hz:5G

Feature

Details

4.4.1.

Control Specifications

4.4.2.

Current Loop

Feature

Details

Controller type

Vector, digital

Compensation for bus voltage
variations

“On-the-fly” automatic gain scheduling

Motor types

AC brushless (sinusoidal)
DC brushless (trapezoidal)
DC brush
Linear motors
"Voice" coils

Current control

Fully digital
Sinusoidal with vector control
Programmable PI control filter based on a
pair of PI controls of AC current signals and
constant power at high speed

Current loop bandwidth

< 2.5 kHz

Current loop sampling time

Programmable 70 to 120 µsec

Current sampling rate

Up to 16 kHz; default 11 kHz

Advertising