Auxiliary feedback port (input mode ya[4]= 2, 0) – ElmoMC SimplIQ Digital Servo Drives-Whistle Installation Guide User Manual

Page 66

Advertising
background image

Whistle and Tweeter Installation Guide

Technical Specifications

MAN-WHTWIG (Ver. 1.604)

www.elmomc.com

66

4.5.4.

Auxiliary Feedback Port (Input mode YA[4]= 2, 0)

Feature

Details

Encoder input,
pulse and direction input

A, B, Index
Single ended

Output current capability

V

In

Low: 0 V < V

IL

< 0.8 V

V

In

High: 2 V < V

IH

< 5 V

Maximum absolute voltage: 0 < V

In

< 5.5 V

Input current: ±1 µA

Available as options

Single-ended Encoder inputs
Pulse and Direction inputs

Edge separation between A & B

Programmable number of clocks to allow adequate
noise filtering at remote receiver of emulated encoder
signals

Index (marker):

Length of pulse is one quadrature (one quarter of an
encoder cycle) and synchronized to A&B

Figure 35: Auxiliary Feedback - Encoder Phase Diagram

Advertising
This manual is related to the following products: