I/os, Digital input interfaces – ElmoMC SimplIQ Digital Servo Drives-Whistle Installation Guide User Manual

Page 67

Advertising
background image

Whistle and Tweeter Installation Guide

Technical Specifications

MAN-WHTWIG (Ver. 1.604)

www.elmomc.com

67

4.6. I/Os

The Whistle and Tweeter have:

6 Digital Inputs

2 Digital Outputs

1 Analog Input

4.6.1.

Digital Input Interfaces

Feature

Details

Type of input

Optically isolated
All six inputs share one signal return line

Input current
for all inputs

Iin = 2.4 mA @ Vin = 5 V

High-level input voltage

2.5 V < Vin < 10 V, 5 V typical

Low-level input voltage

0 V < Vin < 1 V

Minimum pulse width

> 4 x TS, where TS is sampling time

Execution time (all inputs):
the time from application of
voltage on input until execution
is complete

If input is set to one of the built-in functions — Home,
Inhibit, Hard Stop, Soft Stop, Hard and Soft Stop,
Forward Limit, Reverse Limit or Begin — execution is
immediate upon detection: 0<T<4xTS
If input is set to General input, execution depends on
program. Typical execution time: ≅ 0.5 msec.

High-speed inputs – 5 & 6
minimum pulse width, in high-
speed mode

T < 5 µsec

Notes:

Home mode is high-speed mode and can be used for
fast capture and precise homing.
High speed input has a digital filter set to same value
as digital filter (EF) of main encoder.
Highest speed is achieved when turning on
optocouplers.

Figure 36: Digital Input Schematic

Rin = 1.43K

Advertising
This manual is related to the following products: