Enerpac CLS-Series User Manual

Instruction sheet, Cll, clr and cls high tonnage cylinders

Advertising
background image

1

Instruction Sheet

CLL, CLR and CLS

High Tonnage Cylinders

maximum pressure 700 bar [10.000 psi]

EIS 67.116-1 10/2011 Rev. F

1.0 ImpoRTanT RECEIvIng InSTRuCTIonS

Visually inspect all components for shipping damage.

Shipping damage is not covered by warranty. If

shipping damage is found notify carrier at once. The

carrier is responsible for all repair and replacement

costs resulting from damage in shipment.

safety

first

Read all instructions, warnings and cautions carefully.

Follow all safety precautions to avoid personal

injury or property damage during system operation.

Enerpac cannot be responsible for damage or

injury resulting from unsafe product use, lack of

maintenance or incorrect product and/or system

operation. Contact Enerpac when in doubt as to the

safety precautions and applications.

To pRoTECT youR waRRanTy, uSE only

EnERpaC hydRaulIC oIl.

2.0 pRoduCT dESCRIpTIon

2.1 CLL-cylinders

Single-acting, load return cylinders with an overflow

oilport for stroke restriction. Cll cylinders are

provided with a fully threaded plunger and a safety

lock nut for positive loadholding operations. Cll

cylinders do not have a stopring. If mounting holes

are drilled in the cylinder bottom these are metric.

2.2 CLS cylinders

Single-acting, load return cylinders with an overflow

oilport for stroke restriction. ClS cylinders do not

have a stopring. If mounting holes are drilled in the

cylinder bottom these are metric.

2.3 CLR cylinders

double-acting, hydraulic return cylinders with a

safety valve in the retract side to prevent accidental

over pressurization. If mounting holes are drilled in

the cylinder bottom these are metric.

3.0 gEnERaL SaFETy ISSuES

Failure to comply with following cautions and warnings

could cause equipment damage or personal injury.

WaRnIng: CLL and CLS cylinders are

noT equipped with a stopring to retain

the plunger. To prevent plunger over -

extension, a port is provided to vent the oil

out of the cylinder as the plunger reaches the maximum

stroke. when the red line around the plunger

becomes visible, the plunger is at maximum extension.

Further extension could result in the plunger being

forced out of the cylinder. See illustration 1 below.

index:

English Instruction Sheet ............................................................................................ page ................... 1-3

Français Notice d’Emploi ............................................................................................. page ................... 4-6

Deutsch Bedienungsanleitung ..................................................................................... Seite ................... 7-9

Italiano Manuale Istruzioni .......................................................................................... pagina ............ 10-12

Español Instrucciones ................................................................................................. página ............ 13-15

Nederlands Gebruikershandleiding ............................................................................. pagina ............ 16-18

Svenska Instruktionsblad ............................................................................................ sida ................ 19-21

Ελληνικά ..................................................................................................................... ....................... 22-25

Português .................................................................................................................... página ............ 26-28

illustration 1 - CLL and CLS cylinders

REd LInE

lock nut
Cll only

plunger Travel
Restriction port

plunger shown at maximum extension

Advertising
This manual is related to the following products: